CVE-2019-13924
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALAN…
Mitigation
- Upgrade SCALANCE X-200 switch family (incl. SIPLUS NET variants) to 5.2.4 or later.
- Upgrade SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) to 4.1.3 or later.
Who should check
- Anyone running Siemens SCALANCE S602 All versions < V4.1
- Anyone running Siemens SCALANCE S612 All versions < V4.1
- Anyone running Siemens SCALANCE S623 All versions < V4.1
- Anyone running Siemens SCALANCE S627-2M All versions < V4.1
- Anyone running Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) All versions < 5.2.4
- Anyone running Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) All versions < V5.5.0
- Anyone running Siemens SCALANCE X-200RNA switch family All versions < V3.2.7
- Anyone running Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) All versions < 4.1.3
Vulnerability facts
- Affected
- Siemens SCALANCE S602 All versions < V4.1; Siemens SCALANCE S612 All versions < V4.1; Siemens SCALANCE S623 All versions < V4.1; Siemens SCALANCE S627-2M All versions < V4.1; Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) All versions < 5.2.4; Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) All versions < V5.5.0; Siemens SCALANCE X-200RNA switch family All versions < V3.2.7; Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) All versions < 4.1.3
- Fixed in
- Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) 5.2.4, Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) 4.1.3
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.4 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: None
- EPSS
- 0.83% chance of exploitation in 30 days (percentile 55, 2026-11-26)
- CWE
- CWE-693
- Modified
Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SCALANCE S602 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE S612 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE S623 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE S627-2M | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) | All versions < 5.2.4 | — | cvelist |
| Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | All versions < V5.5.0 | — | cvelist |
| Siemens SCALANCE X-200RNA switch family | All versions < V3.2.7 | — | cvelist |
| Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) | All versions < 4.1.3 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-13924. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-13924.md Affected: Siemens SCALANCE S602 All versions < V4.1; Siemens SCALANCE S612 All versions < V4.1; Siemens SCALANCE S623 All versions < V4.1; Siemens SCALANCE S627-2M All versions < V4.1; Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) All versions < 5.2.4; Siemens SCALANCE X-200IRT switch fami… Fixed in: Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) 5.2.4, Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) 4.1.3 Steps: 1. Search this machine and project for Siemens SCALANCE S602, Siemens SCALANCE S612, Siemens SCALANCE S623, Siemens SCALANCE S627-2M, Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants), Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2019-13924 being exploited?
There is no confirmed exploitation: CVE-2019-13924 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.83% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-13924?
Medium: CVSS 5.4 (v3.1, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2019-13924?
Siemens SCALANCE S602 All versions < V4.1; Siemens SCALANCE S612 All versions < V4.1; Siemens SCALANCE S623 All versions < V4.1; Siemens SCALANCE S627-2M All versions < V4.1; Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) All versions < 5.2.4; Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) All versions < V5.5.0; Siemens SCALANCE X-200RNA switch family All versions < V3.2.7; Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) All versions < 4.1.3.
Is there a fix for CVE-2019-13924?
Yes. Fixed in Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) 5.2.4, Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) 4.1.3. Upgrade SCALANCE X-200 switch family (incl. SIPLUS NET variants) to 5.2.4 or later. Upgrade SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) to 4.1.3 or later.
How do I check if I'm affected by CVE-2019-13924?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.