CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of t…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens AG SIMATIC WinAC RTX (F) 2010 All versions < SP3 Update 1
Vulnerability facts
- Affected
- Siemens AG SIMATIC WinAC RTX (F) 2010 All versions < SP3 Update 1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 1.37% chance of exploitation in 30 days (percentile 72, 2026-11-26)
- CWE
- CWE-410
- Modified
Description
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens AG SIMATIC WinAC RTX (F) 2010 | All versions < SP3 Update 1 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-13921. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-13921.md Affected: Siemens AG SIMATIC WinAC RTX (F) 2010 All versions < SP3 Update 1 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens AG SIMATIC WinAC RTX (F) 2010: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2019-13921 being exploited?
There is no confirmed exploitation: CVE-2019-13921 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.37% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-13921?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2019-13921?
Siemens AG SIMATIC WinAC RTX (F) 2010 All versions < SP3 Update 1.
Is there a fix for CVE-2019-13921?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2019-13921?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.