CVE-2019-13549
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mec…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Rittal Chiller SK 3232-Series Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4
Vulnerability facts
- Affected
- Rittal Chiller SK 3232-Series Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- EPSS
- 1.03% chance of exploitation in 30 days (percentile 63, 2026-11-26)
- CWE
- CWE-306
- Modified
Description
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rittal Chiller SK 3232-Series | Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-13549. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-13549.md Affected: Rittal Chiller SK 3232-Series Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rittal Chiller SK 3232-Series: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2019-13549 being exploited?
There is no confirmed exploitation: CVE-2019-13549 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.03% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-13549?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2019-13549?
Rittal Chiller SK 3232-Series Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4.
Is there a fix for CVE-2019-13549?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2019-13549?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.