CVE-2019-13531

MEDIUM 4.8EPSS 25%

Medtronic Valleylab FT10 and LS10 Improper Authentication

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) <= 2.1.0; <= 2.0.3
  • Anyone running Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) <= 1.20.2

Vulnerability facts

Affected
Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) <= 2.1.0; <= 2.0.3; Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) <= 1.20.2
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
4.8 (v3.1, CNA)CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Physical
  • Attack complexity: High
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: Low
EPSS
0.39% chance of exploitation in 30 days (percentile 25, 2026-11-26)
CWE
CWE-287
Published
Modified

Description

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.

Affected and fixed versions

Package / productAffectedFixedSource
Medtronic Valleylab FT10 Energy Platform (VLFT10GEN)<= 2.1.0; <= 2.0.3—cvelist
Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States)<= 1.20.2—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-13531. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-13531.md
Affected: Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) <= 2.1.0; <= 2.0.3; Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) <= 1.20.2
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Medtronic Valleylab FT10 Energy Platform (VLFT10GEN), Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-13531 being exploited?

There is no confirmed exploitation: CVE-2019-13531 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.39% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-13531?

Medium: CVSS 4.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2019-13531?

Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) <= 2.1.0; <= 2.0.3; Medtronic Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) <= 1.20.2.

Is there a fix for CVE-2019-13531?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-13531?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors