CVE-2019-10922

CRITICAL 9.8EPSS 86%

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens AG SIMATIC PCS 7 V8.0 and earlier All versions
  • Anyone running Siemens AG SIMATIC PCS 7 V8.1 and newer All versions
  • Anyone running Siemens AG SIMATIC WinCC V7.2 and earlier All versions
  • Anyone running Siemens AG SIMATIC WinCC V7.3 and newer All versions

Vulnerability facts

Affected
Siemens AG SIMATIC PCS 7 V8.0 and earlier All versions; Siemens AG SIMATIC PCS 7 V8.1 and newer All versions; Siemens AG SIMATIC WinCC V7.2 and earlier All versions; Siemens AG SIMATIC WinCC V7.3 and newer All versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
2.64% chance of exploitation in 30 days (percentile 86, 2026-11-26)
CWE
CWE-306
Published
Modified

Description

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens AG SIMATIC PCS 7 V8.0 and earlierAll versions—cvelist
Siemens AG SIMATIC PCS 7 V8.1 and newerAll versions—cvelist
Siemens AG SIMATIC WinCC V7.2 and earlierAll versions—cvelist
Siemens AG SIMATIC WinCC V7.3 and newerAll versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-10922. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-10922.md
Affected: Siemens AG SIMATIC PCS 7 V8.0 and earlier All versions; Siemens AG SIMATIC PCS 7 V8.1 and newer All versions; Siemens AG SIMATIC WinCC V7.2 and earlier All versions; Siemens AG SIMATIC WinCC V7.3 and newer All versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG SIMATIC PCS 7 V8.0 and earlier, Siemens AG SIMATIC PCS 7 V8.1 and newer, Siemens AG SIMATIC WinCC V7.2 and earlier, Siemens AG SIMATIC WinCC V7.3 and newer: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-10922 being exploited?

There is no confirmed exploitation: CVE-2019-10922 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.64% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-10922?

Critical: CVSS 9.8 (v3.1, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2019-10922?

Siemens AG SIMATIC PCS 7 V8.0 and earlier All versions; Siemens AG SIMATIC PCS 7 V8.1 and newer All versions; Siemens AG SIMATIC WinCC V7.2 and earlier All versions; Siemens AG SIMATIC WinCC V7.3 and newer All versions.

Is there a fix for CVE-2019-10922?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-10922?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.