# CVE-2019-0011: Junos OS: Kernel crash after processing specific incoming packet to the out of band management interface (CVE-2019-0011)

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.5
- **CVSS:** 6.5 (v3.0, CNA) `CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.64% (percentile 45, 2026-11-26)
- **Published:** 2019-01-15T21:00:00.000Z
- **Modified:** 2026-06-17T02:07:30.223Z

## Who should check

- Anyone running Juniper Networks Junos OS \>= 17.2, \< 17.2R1-S7, 17.2R3; \>= 17.3, \< 17.3R3-S3; \>= 17.4, \< 17.4R1-S4, 17.4R2; \>= 17.2X75, \< 17.2X75-D110; \>= 18.1, \< 18.1R2

## Description

The Junos OS kernel crashes after processing a specific incoming packet to the out of band management interface (such as fxp0, me0, em0, vme0) destined for another address. By continuously sending this type of packet, an attacker can repeatedly crash the kernel causing a sustained Denial of Service. Affected releases are Juniper Networks Junos OS: 17.2 versions prior to 17.2R1-S7, 17.2R3; 17.3 versions prior to 17.3R3-S3; 17.4 versions prior to 17.4R1-S4, 17.4R2; 17.2X75 versions prior to 17.2X75-D110; 18.1 versions prior to 18.1R2.

## Affected and fixed versions

- Juniper Networks Junos OS: \>= 17.2, \< 17.2R1-S7, 17.2R3; \>= 17.3, \< 17.3R3-S3; \>= 17.4, \< 17.4R1-S4, 17.4R2; \>= 17.2X75, \< 17.2X75-D110; \>= 18.1, \< 18.1R2 (cvelist)

## Mitigation

- Upgrade Junos OS to 18.1R2 or later.
- Vendor workaround: Apply a firewall filter on the management interface which permits only the necessary traffic on management interface to the device's local address, such as SNMP, SSH, or other management traffic and drops everything else.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2019-0011. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-0011.md
Affected: Juniper Networks Junos OS >= 17.2, < 17.2R1-S7, 17.2R3; >= 17.3, < 17.3R3-S3; >= 17.4, < 17.4R1-S4, 17.4R2; >= 17.2X75, < 17.2X75-D110; >= 18.1, < 18.1R2
Fixed in: Juniper Networks Junos OS 17.2R1-S7, Juniper Networks Junos OS 17.3R3-S3, Juniper Networks Junos OS 17.4R1-S4, Juniper Networks Junos OS 17.2X75-D110, Juniper Networks Junos OS 18.1R2

Steps:
1. Search this machine and project for Juniper Networks Junos OS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2019-0011 being exploited?

There is no confirmed exploitation: CVE-2019-0011 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.64% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2019-0011?

Medium: CVSS 6.5 (v3.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2019-0011?

Juniper Networks Junos OS \>= 17.2, \< 17.2R1-S7, 17.2R3; \>= 17.3, \< 17.3R3-S3; \>= 17.4, \< 17.4R1-S4, 17.4R2; \>= 17.2X75, \< 17.2X75-D110; \>= 18.1, \< 18.1R2.

### Is there a fix for CVE-2019-0011?

Yes. Fixed in Juniper Networks Junos OS 17.2R1-S7, Juniper Networks Junos OS 17.3R3-S3, Juniper Networks Junos OS 17.4R1-S4, Juniper Networks Junos OS 17.2X75-D110, Juniper Networks Junos OS 18.1R2. Upgrade Junos OS to 18.1R2 or later. Vendor workaround: Apply a firewall filter on the management interface which permits only the necessary traffic on management interface to the device's local address, such as SNMP, SSH, or other management traffic and drops everything else.

### How do I check if I'm affected by CVE-2019-0011?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://kb.juniper.net/JSA10911>
- other: <http://www.securityfocus.com/bid/106534>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2019-0011>

HTML: <https://flawdb.com/CVE-2019-0011> · JSON: <https://flawdb.com/api/v1/entries/CVE-2019-0011>