CVE-2018-8868
Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
Mitigation
- Vendor workaround: Medtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- * Maintain good physical controls over the home monitor as the best mitigation to these vulnerabilities.
- * Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system.
- * Report any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative.
- Medtronic has released additional patient focused information, at the following location:
- https://www.medtronic.com/security
Who should check
- Anyone running Medtronic 24950 MyCareLink Monitor All versions
- Anyone running Medtronic 24952 MyCareLink Monitor All versions
Vulnerability facts
- Affected
- Medtronic 24950 MyCareLink Monitor All versions; Medtronic 24952 MyCareLink Monitor All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.2 (v3.1, CNA)CVSS:3.1/AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Physical
- Attack complexity: High
- Privileges required: Low
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: High
- Integrity impact: Low
- Availability impact: Low
- EPSS
- 0.34% chance of exploitation in 30 days (percentile 19, 2026-11-26)
- CWE
- CWE-749
- Modified
Description
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-8868. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-8868.md Affected: Medtronic 24950 MyCareLink Monitor All versions; Medtronic 24952 MyCareLink Monitor All versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Medtronic 24950 MyCareLink Monitor, Medtronic 24952 MyCareLink Monitor: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2018-8868 being exploited?
There is no confirmed exploitation: CVE-2018-8868 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-8868?
Medium: CVSS 6.2 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2018-8868?
Medtronic 24950 MyCareLink Monitor All versions; Medtronic 24952 MyCareLink Monitor All versions.
Is there a fix for CVE-2018-8868?
No fixed version is listed in the sources yet. Vendor workaround: Medtronic recommends users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: * Maintain good physical controls over the home monitor as the best mitigation to these vulnerabilities. * Only use home monitors obtained directly from their healthcare provider or a Medtronic representative to ensure integrity of the system. * Report any concerning behavior regarding their home monitor to their healthcare provider or a Medtronic representative. Medtronic has released additional patient focused information, at the following location: https://www.medtronic.com/security
How do I check if I'm affected by CVE-2018-8868?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.