Affected
Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
6.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: None
EPSS
0.90% chance of exploitation in 30 days (percentile 58, 2026-11-26)
CWE
CWE-79
Published
Modified

Description

An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on.

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-7810. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-7810.md
Affected: Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-7810 being exploited?

There is no confirmed exploitation: CVE-2018-7810 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.90% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-7810?

Medium: CVSS 6.1 (v3.0, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2018-7810?

Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200.

Is there a fix for CVE-2018-7810?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-7810?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors