CVE-2018-7777
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider El…
Also known as EDB-47991
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric SE U.Motion U.motion Builder Software, all versions prior to v1.3.4
Vulnerability facts
- Affected
- Schneider Electric SE U.Motion U.motion Builder Software, all versions prior to v1.3.4
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, login needed
- CVSS
- 8.8 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 31.80% chance of exploitation in 30 days (percentile 99, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric SE U.Motion | U.motion Builder Software, all versions prior to v1.3.4 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-7777. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-7777.md Affected: Schneider Electric SE U.Motion U.motion Builder Software, all versions prior to v1.3.4 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric SE U.Motion: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2018-7777 being exploited?
There is no confirmed exploitation: CVE-2018-7777 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 31.80% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-7777?
High: CVSS 8.8 (v3.0, scored by NVD). Remote, login needed.
Which versions are affected by CVE-2018-7777?
Schneider Electric SE U.Motion U.motion Builder Software, all versions prior to v1.3.4.
Is there a fix for CVE-2018-7777?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-7777?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.