CVE-2018-7522
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4
Vulnerability facts
- Affected
- Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.7 (v3.0, NVD)CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.42% chance of exploitation in 30 days (percentile 28, 2026-11-26)
- CWE
- CWE-119
- Modified
Description
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric Triconex Tricon | MP model 3008 firmware versions 10.0-10.4 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-7522. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-7522.md Affected: Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric Triconex Tricon: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2018-7522 being exploited?
There is no confirmed exploitation: CVE-2018-7522 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.42% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-7522?
Medium: CVSS 6.7 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2018-7522?
Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4.
Is there a fix for CVE-2018-7522?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-7522?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.