Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2018-7119

HIGH 7.0EPSS 17%

A Local Disclosure of Sensitive Information vulnerability was identified in HPE NonStop Safeguard earlier than version…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY Product SAFEGUARD All prior versions before SPR T9750L01^AIC or T9750H05^AIH; and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prior versions before T6533L01^ADU or T6533H05^ADW; all versions on H-series

Vulnerability facts

Affected
HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY Product SAFEGUARD All prior versions before SPR T9750L01^AIC or T9750H05^AIH; and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prior versions before T6533L01^ADU or T6533H05^ADW; all versions on H-series
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.0 (v3.0, NVD)CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: High
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.32% chance of exploitation in 30 days (percentile 17, 2026-11-26)
Published
Modified

Description

A Local Disclosure of Sensitive Information vulnerability was identified in HPE NonStop Safeguard earlier than version SPR T9750L01^AIC or T9750H05^AIH, and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prior versions before T6533L01^ADU or T6533H05^ADW, and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND and all versions on H-series . Note that some commands in NonStop Safeguard and NonStop Standard Security software require username and password to be passed as command line parameters, which may lead to a local disclosure of the credentials.

Affected and fixed versions

Package / productAffectedFixedSource
HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY ProductSAFEGUARD All prior versions before SPR T9750L01^AIC or T9750H05^AIH; and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prior versions before T6533L01^ADU or T6533H05^ADW; all versions on H-series—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-7119. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-7119.md
Affected: HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY Product SAFEGUARD All prior versions before SPR T9750L01^AIC or T9750H05^AIH; and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prio…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY Product: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-7119 being exploited?

There is no confirmed exploitation: CVE-2018-7119 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.32% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-7119?

High: CVSS 7.0 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2018-7119?

HPE NonStop SAFEGAURD and NonStop H-series STDSEC-STANDARD SECURITY Product SAFEGUARD All prior versions before SPR T9750L01^AIC or T9750H05^AIH; and later versions when the PASSWORD-PROMPT configuration attribute is not set to BLIND; all versions on H-series. STDSEC-STANDARD SECURITY PROD All prior versions before T6533L01^ADU or T6533H05^ADW; all versions on H-series.

Is there a fix for CVE-2018-7119?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-7119?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors