CVE-2018-3954
Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Versio…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Linksys ESeries E1200 Firmware Version 2.0.09
- Anyone running Linksys ESeries E2500 Firmware Version 3.0.04
Vulnerability facts
- Affected
- Linksys ESeries E1200 Firmware Version 2.0.09; Linksys ESeries E2500 Firmware Version 3.0.04
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, login needed
- CVSS
- 7.2 (v3.0, CNA)CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 3.38% chance of exploitation in 30 days (percentile 90, 2026-11-26)
- CWE
- CWE-78
- Modified
Description
Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAMData entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-3954. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-3954.md Affected: Linksys ESeries E1200 Firmware Version 2.0.09; Linksys ESeries E2500 Firmware Version 3.0.04 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Linksys ESeries E1200, Linksys ESeries E2500: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2018-3954 being exploited?
There is no confirmed exploitation: CVE-2018-3954 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 3.38% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-3954?
High: CVSS 7.2 (v3.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2018-3954?
Linksys ESeries E1200 Firmware Version 2.0.09; Linksys ESeries E2500 Firmware Version 3.0.04.
Is there a fix for CVE-2018-3954?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-3954?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.