CVE-2018-25090
Wago: Improper Neutralization of Input During Web Page Generation in multiple devices
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running WAGO Controller BACnet/IP <= FW13
- Anyone running WAGO Controller BACnet MS/TP <= FW13
- Anyone running WAGO Ethernet Controller 3rd Generation <= FW13
- Anyone running WAGO Fieldbus Coupler Ethernet 3rd Generation <= FW13
Vulnerability facts
- Affected
- WAGO Controller BACnet/IP <= FW13; WAGO Controller BACnet MS/TP <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Fieldbus Coupler Ethernet 3rd Generation <= FW13
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.4 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: None
- EPSS
- 0.40% chance of exploitation in 30 days (percentile 26, 2026-11-26)
- CWE
- CWE-79
- Modified
Description
An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required. This leads to a limited impact of confidentiality and integrity but no impact of availability.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-25090. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-25090.md Affected: WAGO Controller BACnet/IP <= FW13; WAGO Controller BACnet MS/TP <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Fieldbus Coupler Ethernet 3rd Generation <= FW13 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for WAGO Controller BACnet/IP, WAGO Controller BACnet MS/TP, WAGO Ethernet Controller 3rd Generation, WAGO Fieldbus Coupler Ethernet 3rd Generation: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2018-25090 being exploited?
There is no confirmed exploitation: CVE-2018-25090 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.40% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-25090?
Medium: CVSS 5.4 (v3.1, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2018-25090?
WAGO Controller BACnet/IP <= FW13; WAGO Controller BACnet MS/TP <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Ethernet Controller 3rd Generation <= FW13; WAGO Fieldbus Coupler Ethernet 3rd Generation <= FW13.
Is there a fix for CVE-2018-25090?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-25090?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.