Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2018-16557

HIGH 8.2EPSS 54%

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (A…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC S7-400 CPU 412-1 DP V7 All versions
  • Anyone running Siemens SIMATIC S7-400 CPU 412-2 DP V7 All versions
  • Anyone running Siemens SIMATIC S7-400 CPU 414-2 DP V7 All versions
  • Anyone running Siemens SIMATIC S7-400 CPU 414-3 DP V7 All versions
  • Anyone running Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3
  • Anyone running Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions < V7.0.3
  • Anyone running Siemens SIMATIC S7-400 CPU 416-2 DP V7 All versions
  • Anyone running Siemens SIMATIC S7-400 CPU 416-3 DP V7 All versions

Vulnerability facts

Affected
Siemens SIMATIC S7-400 CPU 412-1 DP V7 All versions; Siemens SIMATIC S7-400 CPU 412-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 416-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416-3 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 416F-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 417-4 DP V7 All versions; Siemens SIMATIC S7-400 CPU 412-2 PN V7 All versions < V7.0.3; Siemens SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) All versions < V6.0.9; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) All versions < V8.2.1; Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3; Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 All versions < V7.0.3; Siemens SIPLUS S7-400 CPU 416-3 V7 All versions; Siemens SIPLUS S7-400 CPU 417-4 V7 All versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
8.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:COpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: Low
  • Availability impact: High
  • E: P
  • RL: O
  • RC: C
EPSS
0.82% chance of exploitation in 30 days (percentile 54, 2026-11-26)
CWE
CWE-347
Published
Modified

Description

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC S7-400 CPU 412-1 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 412-2 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 414-2 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 414-3 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIMATIC S7-400 CPU 416-2 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 416-3 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIMATIC S7-400 CPU 416F-2 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIMATIC S7-400 CPU 417-4 DP V7All versions—cvelist
Siemens SIMATIC S7-400 CPU 412-2 PN V7All versions < V7.0.3—cvelist
Siemens SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)All versions < V6.0.9—cvelist
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants)All versions < V8.2.1—cvelist
Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7All versions < V7.0.3—cvelist
Siemens SIPLUS S7-400 CPU 416-3 V7All versions—cvelist
Siemens SIPLUS S7-400 CPU 417-4 V7All versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-16557. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-16557.md
Affected: Siemens SIMATIC S7-400 CPU 412-1 DP V7 All versions; Siemens SIMATIC S7-400 CPU 412-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC S7-400 CPU 412-1 DP V7, Siemens SIMATIC S7-400 CPU 412-2 DP V7, Siemens SIMATIC S7-400 CPU 414-2 DP V7, Siemens SIMATIC S7-400 CPU 414-3 DP V7, Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7, Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-16557 being exploited?

There is no confirmed exploitation: CVE-2018-16557 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.82% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-16557?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2018-16557?

Siemens SIMATIC S7-400 CPU 412-1 DP V7 All versions; Siemens SIMATIC S7-400 CPU 412-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 DP V7 All versions; Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 416-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416-3 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 416F-2 DP V7 All versions; Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 All versions < V7.0.3; Siemens SIMATIC S7-400 CPU 417-4 DP V7 All versions; Siemens SIMATIC S7-400 CPU 412-2 PN V7 All versions < V7.0.3; Siemens SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) All versions < V6.0.9; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) All versions < V8.2.1; Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 All versions < V7.0.3; Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 All versions < V7.0.3; Siemens SIPLUS S7-400 CPU 416-3 V7 All versions; Siemens SIPLUS S7-400 CPU 417-4 V7 All versions.

Is there a fix for CVE-2018-16557?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-16557?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors