Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2018-14787

HIGH 7.8EPSS 25%

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), a…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Philips IntelliSpace Cardiovascular (ISCV) products IntelliSpace Cardiovascular, Version 3.1 or prior; Xcelera Version 4.1 or prior

Vulnerability facts

Affected
Philips IntelliSpace Cardiovascular (ISCV) products IntelliSpace Cardiovascular, Version 3.1 or prior; Xcelera Version 4.1 or prior
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.8 (v3.1, NVD)CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.39% chance of exploitation in 30 days (percentile 25, 2026-11-26)
CWE
CWE-269
Published
Modified

Description

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions.

Affected and fixed versions

Package / productAffectedFixedSource
Philips IntelliSpace Cardiovascular (ISCV) productsIntelliSpace Cardiovascular, Version 3.1 or prior; Xcelera Version 4.1 or prior—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-14787. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-14787.md
Affected: Philips IntelliSpace Cardiovascular (ISCV) products IntelliSpace Cardiovascular, Version 3.1 or prior; Xcelera Version 4.1 or prior
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Philips IntelliSpace Cardiovascular (ISCV) products: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-14787 being exploited?

There is no confirmed exploitation: CVE-2018-14787 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.39% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-14787?

High: CVSS 7.8 (v3.1, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2018-14787?

Philips IntelliSpace Cardiovascular (ISCV) products IntelliSpace Cardiovascular, Version 3.1 or prior; Xcelera Version 4.1 or prior.

Is there a fix for CVE-2018-14787?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-14787?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors