CVE-2018-13814
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Ou…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) SIMATIC HMI Comfort Panels 4" - 22" : All versions < V14; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V14; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14; SIMATIC WinCC Runtime Advanced : All versions < V14; SIMATIC WinCC Runtime Professional : All versions < V14; SIMATIC WinCC (TIA Portal) : All versions < V14; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions
Vulnerability facts
- Affected
- Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) SIMATIC HMI Comfort Panels 4" - 22" : All versions < V14; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V14; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14; SIMATIC WinCC Runtime Advanced : All versions < V14; SIMATIC WinCC Runtime Professional : All versions < V14; SIMATIC WinCC (TIA Portal) : All versions < V14; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.8 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.68% chance of exploitation in 30 days (percentile 77, 2026-11-26)
- CWE
- CWE-113
- Modified
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) | SIMATIC HMI Comfort Panels 4" - 22" : All versions < V14; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V14; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14; SIMATIC WinCC Runtime Advanced : All versions < V14; SIMATIC WinCC Runtime Professional : All versions < V14; SIMATIC WinCC (TIA Portal) : All versions < V14; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-13814. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-13814.md Affected: Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP…: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2018-13814 being exploited?
There is no confirmed exploitation: CVE-2018-13814 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.68% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-13814?
High: CVSS 8.8 (v3.0, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2018-13814?
Siemens AG SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) SIMATIC HMI Comfort Panels 4" - 22" : All versions < V14; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V14; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14; SIMATIC WinCC Runtime Advanced : All versions < V14; SIMATIC WinCC Runtime Professional : All versions < V14; SIMATIC WinCC (TIA Portal) : All versions < V14; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions.
Is there a fix for CVE-2018-13814?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-13814?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.