CVE-2018-13811
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insuffi…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens AG SIMATIC STEP 7 (TIA Portal) SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1
Vulnerability facts
- Affected
- Siemens AG SIMATIC STEP 7 (TIA Portal) SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.5 (v3.0, NVD)CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.24% chance of exploitation in 30 days (percentile 9, 2026-11-26)
- CWE
- CWE-916
- Modified
Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens AG SIMATIC STEP 7 (TIA Portal) | SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-13811. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-13811.md Affected: Siemens AG SIMATIC STEP 7 (TIA Portal) SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens AG SIMATIC STEP 7 (TIA Portal): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2018-13811 being exploited?
There is no confirmed exploitation: CVE-2018-13811 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.24% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-13811?
Medium: CVSS 5.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2018-13811?
Siemens AG SIMATIC STEP 7 (TIA Portal) SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1.
Is there a fix for CVE-2018-13811?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-13811?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.