CVE-2018-13807
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SC…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414 SCALANCE X300 : All versions < V4.0.0; SCALANCE X408 : All versions < V4.0.0; SCALANCE X414 : All versions
Vulnerability facts
- Affected
- Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414 SCALANCE X300 : All versions < V4.0.0; SCALANCE X408 : All versions < V4.0.0; SCALANCE X414 : All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.6 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 4.13% chance of exploitation in 30 days (percentile 92, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414 | SCALANCE X300 : All versions < V4.0.0; SCALANCE X408 : All versions < V4.0.0; SCALANCE X414 : All versions | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-13807. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-13807.md Affected: Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414 SCALANCE X300 : All versions < V4.0.0; SCALANCE X408 : All versions < V4.0.0; SCALANCE X414 : All versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2018-13807 being exploited?
There is no confirmed exploitation: CVE-2018-13807 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 4.13% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-13807?
High: CVSS 8.6 (v3.0, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2018-13807?
Siemens AG SCALANCE X300, SCALANCE X408, SCALANCE X414 SCALANCE X300 : All versions < V4.0.0; SCALANCE X408 : All versions < V4.0.0; SCALANCE X414 : All versions.
Is there a fix for CVE-2018-13807?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-13807?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.