Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2018-13799

CRITICAL 9.1EPSS 83%

A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access co…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens AG SIMATIC WinCC OA V3.14 and prior SIMATIC WinCC OA V3.14 and prior : All versions < V3.14-P021

Vulnerability facts

Affected
Siemens AG SIMATIC WinCC OA V3.14 and prior SIMATIC WinCC OA V3.14 and prior : All versions < V3.14-P021
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: High
EPSS
2.22% chance of exploitation in 30 days (percentile 83, 2026-11-26)
CWE
CWE-269
Published
Modified

Description

A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens AG SIMATIC WinCC OA V3.14 and priorSIMATIC WinCC OA V3.14 and prior : All versions < V3.14-P021—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-13799. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-13799.md
Affected: Siemens AG SIMATIC WinCC OA V3.14 and prior SIMATIC WinCC OA V3.14 and prior : All versions < V3.14-P021
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG SIMATIC WinCC OA V3.14 and prior: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-13799 being exploited?

There is no confirmed exploitation: CVE-2018-13799 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.22% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-13799?

Critical: CVSS 9.1 (v3.0, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2018-13799?

Siemens AG SIMATIC WinCC OA V3.14 and prior SIMATIC WinCC OA V3.14 and prior : All versions < V3.14-P021.

Is there a fix for CVE-2018-13799?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-13799?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors