Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2018-11464

LOW 3.7EPSS 80%

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All v…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3

Vulnerability facts

Affected
Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
3.7 (v3.0, NVD)CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: High
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: Low
EPSS
1.86% chance of exploitation in 30 days (percentile 80, 2026-11-26)
CWE
CWE-248
Published
Modified

Description

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2018-11464. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2018-11464.md
Affected: Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2018-11464 being exploited?

There is no confirmed exploitation: CVE-2018-11464 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.86% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2018-11464?

Low: CVSS 3.7 (v3.0, scored by NVD). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.

Which versions are affected by CVE-2018-11464?

Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3.

Is there a fix for CVE-2018-11464?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2018-11464?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.