CVE-2018-11458
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All v…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3
Vulnerability facts
- Affected
- Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 4.59% chance of exploitation in 30 days (percentile 92, 2026-11-26)
- CWE
- CWE-190
- Modified
Description
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 | SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-11458. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-11458.md Affected: Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2018-11458 being exploited?
There is no confirmed exploitation: CVE-2018-11458 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 4.59% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-11458?
High: CVSS 8.1 (v3.0, scored by NVD). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2018-11458?
Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3.
Is there a fix for CVE-2018-11458?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-11458?