CVE-2018-10619
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3…
Also known as EDB-44892
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior.
Vulnerability facts
- Affected
- ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior.
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.8 (v3.0, NVD)CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 2.67% chance of exploitation in 30 days (percentile 86, 2026-11-26)
- CWE
- CWE-428
- Modified
Description
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway | RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior. | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2018-10619. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2018-10619.md Affected: ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior. Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2018-10619 being exploited?
There is no confirmed exploitation: CVE-2018-10619 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.67% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2018-10619?
High: CVSS 7.8 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2018-10619?
ICS-CERT Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior..
Is there a fix for CVE-2018-10619?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2018-10619?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.