In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service conditi…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3

Vulnerability facts

Affected
Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
6.5 (v3.0, NVD)CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
0.54% chance of exploitation in 30 days (percentile 39, 2026-11-26)
CWE
CWE-20
Published
Modified

Description

In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-9945. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-9945.md
Affected: Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-9945 being exploited?

There is no confirmed exploitation: CVE-2017-9945 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.54% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-9945?

Medium: CVSS 6.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2017-9945?

Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3 Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3.

Is there a fix for CVE-2017-9945?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-9945?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors