# CVE-2017-9658: Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security d…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.5
- **CVSS:** 6.5 (v3.0, NVD) `CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.81% (percentile 54, 2026-11-26)
- **CWE:** CWE-755
- **Published:** 2018-04-30T15:00:00.000Z
- **Modified:** 2026-06-17T01:28:40.127Z

## Who should check

- Anyone running Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18

## Description

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

## Affected and fixed versions

- Philips IntelliVue MX40 Patient Worn Monitor: IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2017-9658. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-9658.md
Affected: Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Philips IntelliVue MX40 Patient Worn Monitor: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2017-9658 being exploited?

There is no confirmed exploitation: CVE-2017-9658 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.81% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2017-9658?

Medium: CVSS 6.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2017-9658?

Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18.

### Is there a fix for CVE-2017-9658?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2017-9658?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://www.usa.philips.com/healthcare/about/customer-support/product-security>
- other: <http://www.securityfocus.com/bid/100813>
- other: <https://ics-cert.us-cert.gov/advisories/ICSMA-17-255-01>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2017-9658>

HTML: <https://flawdb.com/CVE-2017-9658> · JSON: <https://flawdb.com/api/v1/entries/CVE-2017-9658>
