Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-9657

MEDIUM 6.5EPSS 52%

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18

Vulnerability facts

Affected
Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
6.5 (v3.0, NVD)CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
0.77% chance of exploitation in 30 days (percentile 52, 2026-11-26)
CWE
CWE-460
Published
Modified

Description

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

Affected and fixed versions

Package / productAffectedFixedSource
Philips IntelliVue MX40 Patient Worn MonitorIntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-9657. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-9657.md
Affected: Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Philips IntelliVue MX40 Patient Worn Monitor: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-9657 being exploited?

There is no confirmed exploitation: CVE-2017-9657 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.77% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-9657?

Medium: CVSS 6.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2017-9657?

Philips IntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18.

Is there a fix for CVE-2017-9657?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-9657?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors