CVE-2017-9656
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded crede…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Philips DoseWise Portal 1.1.7.333; 2.1.1.3069
Vulnerability facts
- Affected
- Philips DoseWise Portal 1.1.7.333; 2.1.1.3069
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 9.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 2.23% chance of exploitation in 30 days (percentile 83, 2026-11-26)
- CWE
- CWE-798
- Modified
Description
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Philips DoseWise Portal | 1.1.7.333; 2.1.1.3069 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-9656. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-9656.md Affected: Philips DoseWise Portal 1.1.7.333; 2.1.1.3069 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Philips DoseWise Portal: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2017-9656 being exploited?
There is no confirmed exploitation: CVE-2017-9656 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.23% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-9656?
Critical: CVSS 9.1 (v3.0, scored by NVD). Remote, login needed.
Which versions are affected by CVE-2017-9656?
Philips DoseWise Portal 1.1.7.333; 2.1.1.3069.
Is there a fix for CVE-2017-9656?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-9656?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.