CVE-2017-7969
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA An…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric SE PowerSCADA Anywhere Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2
- Anyone running Schneider Electric SE Citect Anywhere version 1.0
Vulnerability facts
- Affected
- Schneider Electric SE PowerSCADA Anywhere Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2; Schneider Electric SE Citect Anywhere version 1.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.8 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.63% chance of exploitation in 30 days (percentile 44, 2026-11-26)
- CWE
- CWE-352
- Modified
Description
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric SE PowerSCADA Anywhere | Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 | — | cvelist |
| Schneider Electric SE Citect Anywhere | version 1.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-7969. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-7969.md Affected: Schneider Electric SE PowerSCADA Anywhere Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2; Schneider Electric SE Citect Anywhere version 1.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric SE PowerSCADA Anywhere, Schneider Electric SE Citect Anywhere: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Patches
FAQ
Is CVE-2017-7969 being exploited?
There is no confirmed exploitation: CVE-2017-7969 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.63% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-7969?
High: CVSS 8.8 (v3.0, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2017-7969?
Schneider Electric SE PowerSCADA Anywhere Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2; Schneider Electric SE Citect Anywhere version 1.0.
Is there a fix for CVE-2017-7969?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-7969?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.