Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-7924

HIGH 7.5EPSS 98%

An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Rockwell Automation MicroLogix 1100 Controllers Rockwell Automation MicroLogix 1100 Controllers

Vulnerability facts

Affected
Rockwell Automation MicroLogix 1100 Controllers Rockwell Automation MicroLogix 1100 Controllers
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
22.18% chance of exploitation in 30 days (percentile 98, 2026-11-26)
CWE
CWE-20
Published
Modified

Description

An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition.

Affected and fixed versions

Package / productAffectedFixedSource
Rockwell Automation MicroLogix 1100 ControllersRockwell Automation MicroLogix 1100 Controllers—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-7924. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-7924.md
Affected: Rockwell Automation MicroLogix 1100 Controllers Rockwell Automation MicroLogix 1100 Controllers
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation MicroLogix 1100 Controllers: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-7924 being exploited?

There is no confirmed exploitation: CVE-2017-7924 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 22.18% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-7924?

High: CVSS 7.5 (v3.0, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2017-7924?

Rockwell Automation MicroLogix 1100 Controllers Rockwell Automation MicroLogix 1100 Controllers.

Is there a fix for CVE-2017-7924?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-7924?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors