CVE-2017-7914
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Rockwell Automation PanelView Plus 6 700-1500 Rockwell Automation PanelView Plus 6 700-1500
Vulnerability facts
- Affected
- Rockwell Automation PanelView Plus 6 700-1500 Rockwell Automation PanelView Plus 6 700-1500
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.6 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: High
- EPSS
- 6.56% chance of exploitation in 30 days (percentile 95, 2026-11-26)
- CWE
- CWE-882
- Modified
Description
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rockwell Automation PanelView Plus 6 700-1500 | Rockwell Automation PanelView Plus 6 700-1500 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-7914. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-7914.md Affected: Rockwell Automation PanelView Plus 6 700-1500 Rockwell Automation PanelView Plus 6 700-1500 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rockwell Automation PanelView Plus 6 700-1500: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2017-7914 being exploited?
There is no confirmed exploitation: CVE-2017-7914 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 6.56% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-7914?
High: CVSS 8.6 (v3.0, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2017-7914?
Rockwell Automation PanelView Plus 6 700-1500 Rockwell Automation PanelView Plus 6 700-1500.
Is there a fix for CVE-2017-7914?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-7914?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.