# CVE-2017-6865: A vulnerability has been identified in Primary Setup Tool (PST) (All versions \< V4.2 HF1), SIMATIC Automation Tool (All…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.5
- **CVSS:** 6.5 (v3.0, NVD) `CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.47% (percentile 33, 2026-11-26)
- **CWE:** CWE-20
- **Published:** 2017-05-11T10:00:00.000Z
- **Modified:** 2026-06-17T01:23:14.273Z

## Who should check

- Anyone running Siemens AG Primary Setup Tool (PST) All versions \< V4.2 HF1
- Anyone running Siemens AG SIMATIC Automation Tool All versions \< V3.0
- Anyone running Siemens AG SIMATIC NET PC-Software All versions \< V14 SP1
- Anyone running Siemens AG SIMATIC PCS 7 V8.1 All versions
- Anyone running Siemens AG SIMATIC PCS 7 V8.2 All versions \< V8.2 SP1
- Anyone running Siemens AG SIMATIC STEP 7 (TIA Portal) V13 All versions \< V13 SP2
- Anyone running Siemens AG SIMATIC STEP 7 (TIA Portal) V14 All versions \< V14 SP1
- Anyone running Siemens AG SIMATIC STEP 7 V5.X All versions \< V5.6

## Description

A vulnerability has been identified in Primary Setup Tool (PST) (All versions \< V4.2 HF1), SIMATIC Automation Tool (All versions \< V3.0), SIMATIC NET PC-Software (All versions \< V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \< V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \< V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \< V14 SP1), SIMATIC STEP 7 V5.X (All versions \< V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \< V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \< V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \< V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \< V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \< flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \< V7.3 Update 15), SINEMA Server (All versions \< V14), SINUMERIK 808D Programming Tool (All versions \< V4.7 SP4 HF2), SMART PC Access (All versions \< V2.3), STEP 7 - Micro/WIN SMART (All versions \< V2.3), Security Configuration Tool (SCT) (All versions \< V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.

## Affected and fixed versions

- Siemens AG Primary Setup Tool (PST): All versions \< V4.2 HF1 (cvelist)
- Siemens AG SIMATIC Automation Tool: All versions \< V3.0 (cvelist)
- Siemens AG SIMATIC NET PC-Software: All versions \< V14 SP1 (cvelist)
- Siemens AG SIMATIC PCS 7 V8.1: All versions (cvelist)
- Siemens AG SIMATIC PCS 7 V8.2: All versions \< V8.2 SP1 (cvelist)
- Siemens AG SIMATIC STEP 7 (TIA Portal) V13: All versions \< V13 SP2 (cvelist)
- Siemens AG SIMATIC STEP 7 (TIA Portal) V14: All versions \< V14 SP1 (cvelist)
- Siemens AG SIMATIC STEP 7 V5.X: All versions \< V5.6 (cvelist)
- Siemens AG SIMATIC WinAC RTX 2010 SP2: All versions (cvelist)
- Siemens AG SIMATIC WinAC RTX F 2010 SP2: All versions (cvelist)
- Siemens AG SIMATIC WinCC (TIA Portal) V13: All versions \< V13 SP2 (cvelist)
- Siemens AG SIMATIC WinCC (TIA Portal) V14: All versions \< V14 SP1 (cvelist)
- Siemens AG SIMATIC WinCC V7.2 and prior: All versions (cvelist)
- Siemens AG SIMATIC WinCC V7.3: All versions \< V7.3 Update 15 (cvelist)
- Siemens AG SIMATIC WinCC V7.4: All versions \< V7.4 SP1 Upd1 (cvelist)
- Siemens AG SIMATIC WinCC flexible 2008: All versions \< flexible 2008 SP5 (cvelist)
- Siemens AG SINAUT ST7CC: All versions installed in conjunction with SIMATIC WinCC \< V7.3 Update 15 (cvelist)
- Siemens AG SINEMA Server: All versions \< V14 (cvelist)
- Siemens AG SINUMERIK 808D Programming Tool: All versions \< V4.7 SP4 HF2 (cvelist)
- Siemens AG SMART PC Access: All versions \< V2.3 (cvelist)
- Siemens AG STEP 7 - Micro/WIN SMART: All versions \< V2.3 (cvelist)
- Siemens AG Security Configuration Tool (SCT): All versions \< V5.0 (cvelist)
- Siemens AG Security Configuration Tool (SCT): All versions \< V5.0 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2017-6865. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-6865.md
Affected: Siemens AG Primary Setup Tool (PST) All versions < V4.2 HF1; Siemens AG SIMATIC Automation Tool All versions < V3.0; Siemens AG SIMATIC NET PC-Software All versions < V14 SP1; Siemens AG SIMATIC PCS 7 V8.1 All versions; Siemens AG SIMATIC PCS 7 V8.2 All versions < V8.2 SP1; Siemens AG SIMATIC STEP …
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG Primary Setup Tool (PST), Siemens AG SIMATIC Automation Tool, Siemens AG SIMATIC NET PC-Software, Siemens AG SIMATIC PCS 7 V8.1, Siemens AG SIMATIC PCS 7 V8.2, Siemens AG SIMATIC STEP 7 (TIA Portal) V13: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2017-6865 being exploited?

There is no confirmed exploitation: CVE-2017-6865 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.47% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2017-6865?

Medium: CVSS 6.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2017-6865?

Siemens AG Primary Setup Tool (PST) All versions \< V4.2 HF1; Siemens AG SIMATIC Automation Tool All versions \< V3.0; Siemens AG SIMATIC NET PC-Software All versions \< V14 SP1; Siemens AG SIMATIC PCS 7 V8.1 All versions; Siemens AG SIMATIC PCS 7 V8.2 All versions \< V8.2 SP1; Siemens AG SIMATIC STEP 7 (TIA Portal) V13 All versions \< V13 SP2; Siemens AG SIMATIC STEP 7 (TIA Portal) V14 All versions \< V14 SP1; Siemens AG SIMATIC STEP 7 V5.X All versions \< V5.6; Siemens AG SIMATIC WinAC RTX 2010 SP2 All versions; Siemens AG SIMATIC WinAC RTX F 2010 SP2 All versions; Siemens AG SIMATIC WinCC (TIA Portal) V13 All versions \< V13 SP2; Siemens AG SIMATIC WinCC (TIA Portal) V14 All versions \< V14 SP1; Siemens AG SIMATIC WinCC V7.2 and prior All versions; Siemens AG SIMATIC WinCC V7.3 All versions \< V7.3 Update 15; Siemens AG SIMATIC WinCC V7.4 All versions \< V7.4 SP1 Upd1; Siemens AG SIMATIC WinCC flexible 2008 All versions \< flexible 2008 SP5; Siemens AG SINAUT ST7CC All versions installed in conjunction with SIMATIC WinCC \< V7.3 Update 15; Siemens AG SINEMA Server All versions \< V14; Siemens AG SINUMERIK 808D Programming Tool All versions \< V4.7 SP4 HF2; Siemens AG SMART PC Access All versions \< V2.3; Siemens AG STEP 7 - Micro/WIN SMART All versions \< V2.3; Siemens AG Security Configuration Tool (SCT) All versions \< V5.0; Siemens AG Security Configuration Tool (SCT) All versions \< V5.0.

### Is there a fix for CVE-2017-6865?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2017-6865?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf>
- other: <https://www.securityfocus.com/bid/98366>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2017-6865>

HTML: <https://flawdb.com/CVE-2017-6865> · JSON: <https://flawdb.com/api/v1/entries/CVE-2017-6865>