# CVE-2017-6034: Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.8
- **CVSS:** 9.8 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 5.60% (percentile 94, 2026-11-26)
- **CWE:** CWE-294
- **Published:** 2017-06-30T02:35:00.000Z
- **Modified:** 2026-06-17T01:21:40.227Z

## Who should check

- Anyone running Schneider Electric Modicon Modbus Protocol all versions

## Description

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

## Affected and fixed versions

- Schneider Electric Modicon Modbus Protocol: all versions (cvelist)

## Mitigation

- Vendor workaround: Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.
- 
- 
- 
- Schneider Electric’s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:
- 
-   \*  Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502.
- 
- 
- 
- 
- Schneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:
- 
-   \*  Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;
-   \*  Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and
-   \*  Enable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.
- 
- 
- 
- 
- For additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:
- 
- 
- 
- https://www.se.com/us/en/download/document/SEVD-2017-065-01/

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2017-6034. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-6034.md
Affected: Schneider Electric Modicon Modbus Protocol all versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric Modicon Modbus Protocol: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2017-6034 being exploited?

There is no confirmed exploitation: CVE-2017-6034 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 5.60% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2017-6034?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2017-6034?

Schneider Electric Modicon Modbus Protocol all versions.

### Is there a fix for CVE-2017-6034?

No fixed version is listed in the sources yet. Vendor workaround: Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency.    Schneider Electric’s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures:    \*  Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502.     Schneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures:    \*  Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program;   \*  Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and   \*  Enable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC.     For additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location:    https://www.se.com/us/en/download/document/SEVD-2017-065-01/

### How do I check if I'm affected by CVE-2017-6034?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01>
- other: <http://www.securityfocus.com/bid/97562>
- other: <https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-101-01.json>
- other: <https://www.se.com/us/en/download/document/SEVD-2017-065-01/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2017-6034>

HTML: <https://flawdb.com/CVE-2017-6034> · JSON: <https://flawdb.com/api/v1/entries/CVE-2017-6034>