CVE-2017-6018
An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation do…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running B. Braun Medical SpaceCom B. Braun Medical SpaceCom
Vulnerability facts
- Affected
- B. Braun Medical SpaceCom B. Braun Medical SpaceCom
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 6.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Changed (impact reaches other components)
- Confidentiality impact: Low
- Integrity impact: Low
- Availability impact: None
- EPSS
- 0.95% chance of exploitation in 30 days (percentile 60, 2026-11-26)
- CWE
- CWE-601
- Modified
Description
An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| B. Braun Medical SpaceCom | B. Braun Medical SpaceCom | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-6018. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-6018.md Affected: B. Braun Medical SpaceCom B. Braun Medical SpaceCom Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for B. Braun Medical SpaceCom: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2017-6018 being exploited?
There is no confirmed exploitation: CVE-2017-6018 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.95% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-6018?
Medium: CVSS 6.1 (v3.0, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2017-6018?
B. Braun Medical SpaceCom B. Braun Medical SpaceCom.
Is there a fix for CVE-2017-6018?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-6018?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.