Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-6015

HIGH 7.8EPSS 48%

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Rockwell Automation FactoryTalk Activation FactoryTalk Activation Service, Version 4.00.02 and prior versions.

Vulnerability facts

Affected
Rockwell Automation FactoryTalk Activation FactoryTalk Activation Service, Version 4.00.02 and prior versions.
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.8 (v3.0, NVD)CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.69% chance of exploitation in 30 days (percentile 48, 2026-11-26)
CWE
CWE-428
Published
Modified

Description

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

Affected and fixed versions

Package / productAffectedFixedSource
Rockwell Automation FactoryTalk ActivationFactoryTalk Activation Service, Version 4.00.02 and prior versions.—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-6015. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-6015.md
Affected: Rockwell Automation FactoryTalk Activation FactoryTalk Activation Service, Version 4.00.02 and prior versions.
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation FactoryTalk Activation: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-6015 being exploited?

There is no confirmed exploitation: CVE-2017-6015 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.69% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-6015?

High: CVSS 7.8 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2017-6015?

Rockwell Automation FactoryTalk Activation FactoryTalk Activation Service, Version 4.00.02 and prior versions..

Is there a fix for CVE-2017-6015?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-6015?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors