Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-20216

CRITICAL 9.3PoCEPSS 98%

FLIR Thermal Camera PT-Series firmware version 8.0.0.64 Unauthenticated Remote Command Injection

Also known as EDB-42785

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running FLIR Systems, Inc. FLIR Thermal Camera PT-Series 8.0.0.64

Vulnerability facts

Affected
FLIR Systems, Inc. FLIR Thermal Camera PT-Series 8.0.0.64
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
17.73% chance of exploitation in 30 days (percentile 98, 2026-11-26)
CWE
CWE-78
Published
Modified

Description

FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).

Affected and fixed versions

Package / productAffectedFixedSource
FLIR Systems, Inc. FLIR Thermal Camera PT-Series8.0.0.64—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-20216. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-20216.md
Affected: FLIR Systems, Inc. FLIR Thermal Camera PT-Series 8.0.0.64
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for FLIR Systems, Inc. FLIR Thermal Camera PT-Series: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-20216 being exploited?

There is no confirmed exploitation: CVE-2017-20216 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 17.73% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-20216?

Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2017-20216?

FLIR Systems, Inc. FLIR Thermal Camera PT-Series 8.0.0.64.

Is there a fix for CVE-2017-20216?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-20216?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors