CVE-2017-16745
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.0…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Delta Electronics Delta Industrial Automation Screen Editor Delta Electronics Delta Industrial Automation Screen Editor
Vulnerability facts
- Affected
- Delta Electronics Delta Industrial Automation Screen Editor Delta Electronics Delta Industrial Automation Screen Editor
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 7.8 (v3.0, NVD)CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.05% chance of exploitation in 30 days (percentile 64, 2026-11-26)
- CWE
- CWE-843
- Modified
Description
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type ('type confusion') vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Delta Electronics Delta Industrial Automation Screen Editor | Delta Electronics Delta Industrial Automation Screen Editor | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-16745. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-16745.md Affected: Delta Electronics Delta Industrial Automation Screen Editor Delta Electronics Delta Industrial Automation Screen Editor Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Delta Electronics Delta Industrial Automation Screen Editor: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2017-16745 being exploited?
There is no confirmed exploitation: CVE-2017-16745 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.05% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-16745?
High: CVSS 7.8 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2017-16745?
Delta Electronics Delta Industrial Automation Screen Editor Delta Electronics Delta Industrial Automation Screen Editor.
Is there a fix for CVE-2017-16745?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-16745?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.