CVE-2017-14009
An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticate…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running ProMinent MultiFLEX M10a Controller ProMinent MultiFLEX M10a Controller
Vulnerability facts
- Affected
- ProMinent MultiFLEX M10a Controller ProMinent MultiFLEX M10a Controller
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 6.5 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.73% chance of exploitation in 30 days (percentile 50, 2026-11-26)
- CWE
- CWE-200
- Modified
Description
An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the Change Password feature on the application, the current password for the user is specified in plaintext. This may allow an attacker who has been authenticated to gain access to the password.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| ProMinent MultiFLEX M10a Controller | ProMinent MultiFLEX M10a Controller | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-14009. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-14009.md Affected: ProMinent MultiFLEX M10a Controller ProMinent MultiFLEX M10a Controller Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for ProMinent MultiFLEX M10a Controller: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2017-14009 being exploited?
There is no confirmed exploitation: CVE-2017-14009 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.73% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-14009?
Medium: CVSS 6.5 (v3.0, scored by NVD). Remote, login needed.
Which versions are affected by CVE-2017-14009?
ProMinent MultiFLEX M10a Controller ProMinent MultiFLEX M10a Controller.
Is there a fix for CVE-2017-14009?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-14009?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.