Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-12741

HIGH 8.7EPSS 89%

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller All versions < V4.1.1 Patch 05
  • Anyone running Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 All versions < V4.5
  • Anyone running Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P All versions < V4.5
  • Anyone running Siemens SIMATIC Compact Field Unit All versions
  • Anyone running Siemens SIMATIC ET 200AL IM 157-1 PN < V1.0.2
  • Anyone running Siemens SIMATIC ET 200M (incl. SIPLUS variants) All versions
  • Anyone running Siemens SIMATIC ET 200MP IM 155-5 PN BA < V4.0.2
  • Anyone running Siemens SIMATIC ET 200MP IM 155-5 PN HF < V4.2.0

Vulnerability facts

Affected
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller All versions < V4.1.1 Patch 05; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 All versions < V4.5; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P All versions < V4.5; Siemens SIMATIC Compact Field Unit All versions; Siemens SIMATIC ET 200AL IM 157-1 PN < V1.0.2; Siemens SIMATIC ET 200M (incl. SIPLUS variants) All versions; Siemens SIMATIC ET 200MP IM 155-5 PN BA < V4.0.2; Siemens SIMATIC ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIMATIC ET 200MP IM 155-5 PN ST < V4.1.0; Siemens SIMATIC ET 200pro IM 154-3 PN HF < *; Siemens SIMATIC ET 200pro IM 154-4 PN HF < *; Siemens SIMATIC ET 200SP IM 155-6 PN BA < *; Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) All versions < V1.1.0; Siemens SIMATIC ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIMATIC ET 200SP IM 155-6 PN HS < V4.0.1; Siemens SIMATIC ET 200SP IM 155-6 PN ST < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST BA < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST BA < *; Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN: IO-Link Master All versions; Siemens SIMATIC ET200S (incl. SIPLUS variants) All versions; Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) All versions < V4.2.0; Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions < V4.2.3; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V2.0; Siemens SIMATIC S7-1500 Software Controller All versions < V2.0; Siemens SIMATIC S7-200 SMART All versions < V2.03.01; Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) < V3.X.16; Siemens SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants) < V6.0.8; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) < V6.0.6; Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) < V7.0.2; Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) All versions < V8.2.1; Siemens SIMATIC TDC CP51M1 < V1.1.8; Siemens SIMATIC TDC CPU555 < V1.1.1; Siemens SIMATIC WinAC RTX 2010 All versions < V2010 SP3; Siemens SIMATIC WinAC RTX F 2010 All versions < V2010 SP3; Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) All versions < V2.1.1; Siemens SIMOTION C All versions < V5.1 HF1; Siemens SIMOTION D All versions < V5.1 HF1; Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants) All versions < V4.4 HF26; Siemens SIMOTION P V4.4 and V4.5 All versions < V4.5 HF5; Siemens SIMOTION P V5 All versions < V5.1 HF1; Siemens SINAMICS DCM w. PN All versions < V1.4 SP1 HF6; Siemens SINAMICS DCP w. PN All versions < V1.2 HF2; Siemens SINAMICS G110M w. PN All versions < V4.7 SP9 HF1; Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) All versions < V4.7 SP9 HF1; Siemens SINAMICS G130 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS G130 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS G150 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS G150 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS GH150 V4.7 w. PROFINET All versions < V4.7 SP5 HF7; Siemens SINAMICS GL150 V4.7 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS GM150 V4.7 w. PROFINET All versions < V4.7 HF31; Siemens SINAMICS S110 w. PN All versions < V4.4 SP3 HF6; Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) All versions < V4.7; Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) All versions < V4.7 HF29; Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) All versions < V4.8 HF5; Siemens SINAMICS S150 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS S150 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS SL150 V4.7.0 w. PROFINET All versions < V4.7 HF30; Siemens SINAMICS SL150 V4.7.4 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS SL150 V4.7.5 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS SM120 V4.7 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS V90 w. PN All versions < V1.02; Siemens SINUMERIK 840D sl All versions < V4.8 SP3; Siemens SIPLUS ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN ST < V4.1.0; Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL < V4.1.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN ST < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL < *; Siemens SIRIUS Soft Starter 3RW44 PN All versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
8.7 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
3.31% chance of exploitation in 30 days (percentile 89, 2026-11-26)
CWE
CWE-400
Published
Modified

Description

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet ControllerAll versions < V4.1.1 Patch 05—cvelist
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200All versions < V4.5—cvelist
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200PAll versions < V4.5—cvelist
Siemens SIMATIC Compact Field UnitAll versions—cvelist
Siemens SIMATIC ET 200AL IM 157-1 PN< V1.0.2—cvelist
Siemens SIMATIC ET 200M (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC ET 200MP IM 155-5 PN BA< V4.0.2—cvelist
Siemens SIMATIC ET 200MP IM 155-5 PN HF< V4.2.0—cvelist
Siemens SIMATIC ET 200MP IM 155-5 PN ST< V4.1.0—cvelist
Siemens SIMATIC ET 200pro IM 154-3 PN HF< *—cvelist
Siemens SIMATIC ET 200pro IM 154-4 PN HF< *—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN BA< *—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)All versions < V1.1.0—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN HF< V4.2.0—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN HS< V4.0.1—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN ST< *—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN ST< *—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA< *—cvelist
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA< *—cvelist
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12All versions—cvelist
Siemens SIMATIC ET200ecoPN: IO-Link MasterAll versions—cvelist
Siemens SIMATIC ET200S (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)All versions < V4.2.0—cvelist
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)All versions < V4.2.3—cvelist
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)All versions < V2.0—cvelist
Siemens SIMATIC S7-1500 Software ControllerAll versions < V2.0—cvelist
Siemens SIMATIC S7-200 SMARTAll versions < V2.03.01—cvelist
Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)< V3.X.16—cvelist
Siemens SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)< V6.0.8—cvelist
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)< V6.0.6—cvelist
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)< V7.0.2—cvelist
Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)All versions < V8.2.1—cvelist
Siemens SIMATIC TDC CP51M1< V1.1.8—cvelist
Siemens SIMATIC TDC CPU555< V1.1.1—cvelist
Siemens SIMATIC WinAC RTX 2010All versions < V2010 SP3—cvelist
Siemens SIMATIC WinAC RTX F 2010All versions < V2010 SP3—cvelist
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants)All versions < V2.1.1—cvelist
Siemens SIMOTION CAll versions < V5.1 HF1—cvelist
Siemens SIMOTION DAll versions < V5.1 HF1—cvelist
Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)All versions < V4.4 HF26—cvelist
Siemens SIMOTION P V4.4 and V4.5All versions < V4.5 HF5—cvelist
Siemens SIMOTION P V5All versions < V5.1 HF1—cvelist
Siemens SINAMICS DCM w. PNAll versions < V1.4 SP1 HF6—cvelist
Siemens SINAMICS DCP w. PNAll versions < V1.2 HF2—cvelist
Siemens SINAMICS G110M w. PNAll versions < V4.7 SP9 HF1—cvelist
Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)All versions < V4.7 SP9 HF1—cvelist
Siemens SINAMICS G130 V4.7 w. PNAll versions < V4.7 HF29—cvelist
Siemens SINAMICS G130 V4.8 w. PNAll versions < V4.8 HF4—cvelist
Siemens SINAMICS G150 V4.7 w. PNAll versions < V4.7 HF29—cvelist
Siemens SINAMICS G150 V4.8 w. PNAll versions < V4.8 HF4—cvelist
Siemens SINAMICS GH150 V4.7 w. PROFINETAll versions < V4.7 SP5 HF7—cvelist
Siemens SINAMICS GL150 V4.7 w. PROFINETAll versions < V4.8 SP2—cvelist
Siemens SINAMICS GM150 V4.7 w. PROFINETAll versions < V4.7 HF31—cvelist
Siemens SINAMICS S110 w. PNAll versions < V4.4 SP3 HF6—cvelist
Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)All versions < V4.7—cvelist
Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)All versions—cvelist
Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)All versions < V4.7 HF29—cvelist
Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)All versions < V4.8 HF5—cvelist
Siemens SINAMICS S150 V4.7 w. PNAll versions < V4.7 HF29—cvelist
Siemens SINAMICS S150 V4.8 w. PNAll versions < V4.8 HF4—cvelist
Siemens SINAMICS SL150 V4.7.0 w. PROFINETAll versions < V4.7 HF30—cvelist
Siemens SINAMICS SL150 V4.7.4 w. PROFINETAll versions < V4.8 SP2—cvelist
Siemens SINAMICS SL150 V4.7.5 w. PROFINETAll versions < V4.8 SP2—cvelist
Siemens SINAMICS SM120 V4.7 w. PROFINETAll versions < V4.8 SP2—cvelist
Siemens SINAMICS V90 w. PNAll versions < V1.02—cvelist
Siemens SINUMERIK 840D slAll versions < V4.8 SP3—cvelist
Siemens SIPLUS ET 200MP IM 155-5 PN HF< V4.2.0—cvelist
Siemens SIPLUS ET 200MP IM 155-5 PN HF< V4.2.0—cvelist
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL< V4.2.0—cvelist
Siemens SIPLUS ET 200MP IM 155-5 PN ST< V4.1.0—cvelist
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL< V4.1.0—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN HF< V4.2.0—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN HF< V4.2.0—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL< V4.2.0—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL< *—cvelist
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL< *—cvelist
Siemens SIRIUS Soft Starter 3RW44 PNAll versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-12741. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-12741.md
Affected: Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller All versions < V4.1.1 Patch 05; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 All versions < V4.5; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P All versions < V4.5; Siemens…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, Siemens SIMATIC Compact Field Unit, Siemens SIMATIC ET 200AL IM 157-1 PN, Siem…: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-12741 being exploited?

There is no confirmed exploitation: CVE-2017-12741 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.31% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-12741?

High: CVSS 8.7 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2017-12741?

Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller All versions < V4.1.1 Patch 05; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 All versions < V4.5; Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P All versions < V4.5; Siemens SIMATIC Compact Field Unit All versions; Siemens SIMATIC ET 200AL IM 157-1 PN < V1.0.2; Siemens SIMATIC ET 200M (incl. SIPLUS variants) All versions; Siemens SIMATIC ET 200MP IM 155-5 PN BA < V4.0.2; Siemens SIMATIC ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIMATIC ET 200MP IM 155-5 PN ST < V4.1.0; Siemens SIMATIC ET 200pro IM 154-3 PN HF < *; Siemens SIMATIC ET 200pro IM 154-4 PN HF < *; Siemens SIMATIC ET 200SP IM 155-6 PN BA < *; Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) All versions < V1.1.0; Siemens SIMATIC ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIMATIC ET 200SP IM 155-6 PN HS < V4.0.1; Siemens SIMATIC ET 200SP IM 155-6 PN ST < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST BA < *; Siemens SIMATIC ET 200SP IM 155-6 PN ST BA < *; Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 All versions; Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 All versions; Siemens SIMATIC ET200ecoPN: IO-Link Master All versions; Siemens SIMATIC ET200S (incl. SIPLUS variants) All versions; Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) All versions < V4.2.0; Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions < V4.2.3; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V2.0; Siemens SIMATIC S7-1500 Software Controller All versions < V2.0; Siemens SIMATIC S7-200 SMART All versions < V2.03.01; Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) < V3.X.16; Siemens SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants) < V6.0.8; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) < V6.0.6; Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) < V7.0.2; Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) All versions < V8.2.1; Siemens SIMATIC TDC CP51M1 < V1.1.8; Siemens SIMATIC TDC CPU555 < V1.1.1; Siemens SIMATIC WinAC RTX 2010 All versions < V2010 SP3; Siemens SIMATIC WinAC RTX F 2010 All versions < V2010 SP3; Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) All versions < V2.1.1; Siemens SIMOTION C All versions < V5.1 HF1; Siemens SIMOTION D All versions < V5.1 HF1; Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants) All versions < V4.4 HF26; Siemens SIMOTION P V4.4 and V4.5 All versions < V4.5 HF5; Siemens SIMOTION P V5 All versions < V5.1 HF1; Siemens SINAMICS DCM w. PN All versions < V1.4 SP1 HF6; Siemens SINAMICS DCP w. PN All versions < V1.2 HF2; Siemens SINAMICS G110M w. PN All versions < V4.7 SP9 HF1; Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) All versions < V4.7 SP9 HF1; Siemens SINAMICS G130 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS G130 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS G150 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS G150 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS GH150 V4.7 w. PROFINET All versions < V4.7 SP5 HF7; Siemens SINAMICS GL150 V4.7 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS GM150 V4.7 w. PROFINET All versions < V4.7 HF31; Siemens SINAMICS S110 w. PN All versions < V4.4 SP3 HF6; Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) All versions < V4.7; Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) All versions < V4.7 HF29; Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) All versions < V4.8 HF5; Siemens SINAMICS S150 V4.7 w. PN All versions < V4.7 HF29; Siemens SINAMICS S150 V4.8 w. PN All versions < V4.8 HF4; Siemens SINAMICS SL150 V4.7.0 w. PROFINET All versions < V4.7 HF30; Siemens SINAMICS SL150 V4.7.4 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS SL150 V4.7.5 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS SM120 V4.7 w. PROFINET All versions < V4.8 SP2; Siemens SINAMICS V90 w. PN All versions < V1.02; Siemens SINUMERIK 840D sl All versions < V4.8 SP3; Siemens SIPLUS ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN HF < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL < V4.2.0; Siemens SIPLUS ET 200MP IM 155-5 PN ST < V4.1.0; Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL < V4.1.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL < V4.2.0; Siemens SIPLUS ET 200SP IM 155-6 PN ST < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL < *; Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL < *; Siemens SIRIUS Soft Starter 3RW44 PN All versions.

Is there a fix for CVE-2017-12741?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-12741?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors