Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-12736

HIGH 8.8EPSS 64%

After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens RUGGEDCOM i800 < V4.3.4
  • Anyone running Siemens RUGGEDCOM i800NC < V4.3.4
  • Anyone running Siemens RUGGEDCOM i801 < V4.3.4
  • Anyone running Siemens RUGGEDCOM i801NC < V4.3.4
  • Anyone running Siemens RUGGEDCOM i802 < V4.3.4
  • Anyone running Siemens RUGGEDCOM i802NC < V4.3.4
  • Anyone running Siemens RUGGEDCOM i803 < V4.3.4
  • Anyone running Siemens RUGGEDCOM i803NC < V4.3.4

Vulnerability facts

Affected
Siemens RUGGEDCOM i800 < V4.3.4; Siemens RUGGEDCOM i800NC < V4.3.4; Siemens RUGGEDCOM i801 < V4.3.4; Siemens RUGGEDCOM i801NC < V4.3.4; Siemens RUGGEDCOM i802 < V4.3.4; Siemens RUGGEDCOM i802NC < V4.3.4; Siemens RUGGEDCOM i803 < V4.3.4; Siemens RUGGEDCOM i803NC < V4.3.4; Siemens RUGGEDCOM M2100 < V4.3.4; Siemens RUGGEDCOM M2100NC < V4.3.4; Siemens RUGGEDCOM M2200 < V4.3.4; Siemens RUGGEDCOM M2200NC < V4.3.4; Siemens RUGGEDCOM M969 < V4.3.4; Siemens RUGGEDCOM M969NC < V4.3.4; Siemens RUGGEDCOM RMC30 < V4.3.4; Siemens RUGGEDCOM RMC30NC < V4.3.4; Siemens RUGGEDCOM RMC8388 V4.X < V4.3.4; Siemens RUGGEDCOM RMC8388 V5.X < V5.0.1; Siemens RUGGEDCOM RMC8388NC V4.X < V4.3.4; Siemens RUGGEDCOM RMC8388NC V5.X < V5.0.1; Siemens RUGGEDCOM RP110 < V4.3.4; Siemens RUGGEDCOM RP110NC < V4.3.4; Siemens RUGGEDCOM RS1600 < V4.3.4; Siemens RUGGEDCOM RS1600F < V4.3.4; Siemens RUGGEDCOM RS1600FNC < V4.3.4; Siemens RUGGEDCOM RS1600NC < V4.3.4; Siemens RUGGEDCOM RS1600T < V4.3.4; Siemens RUGGEDCOM RS1600TNC < V4.3.4; Siemens RUGGEDCOM RS400 < V4.3.4; Siemens RUGGEDCOM RS400NC < V4.3.4; Siemens RUGGEDCOM RS401 < V4.3.4; Siemens RUGGEDCOM RS401NC < V4.3.4; Siemens RUGGEDCOM RS416 < V4.3.4; Siemens RUGGEDCOM RS416NC < V4.3.4; Siemens RUGGEDCOM RS416NCv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416NCv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416P < V4.3.4; Siemens RUGGEDCOM RS416PNC < V4.3.4; Siemens RUGGEDCOM RS416PNCv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416PNCv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416Pv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416Pv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416v2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416v2 V5.X < V5.0.1; Siemens RUGGEDCOM RS8000 < V4.3.4; Siemens RUGGEDCOM RS8000A < V4.3.4; Siemens RUGGEDCOM RS8000ANC < V4.3.4; Siemens RUGGEDCOM RS8000H < V4.3.4; Siemens RUGGEDCOM RS8000HNC < V4.3.4; Siemens RUGGEDCOM RS8000NC < V4.3.4; Siemens RUGGEDCOM RS8000T < V4.3.4; Siemens RUGGEDCOM RS8000TNC < V4.3.4; Siemens RUGGEDCOM RS900 < V4.3.4; Siemens RUGGEDCOM RS900 (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900 (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900G < V4.3.4; Siemens RUGGEDCOM RS900G (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900G (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900GNC < V4.3.4; Siemens RUGGEDCOM RS900GNC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900GNC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900GP < V4.3.4; Siemens RUGGEDCOM RS900GPNC < V4.3.4; Siemens RUGGEDCOM RS900L < V4.3.4; Siemens RUGGEDCOM RS900LNC < V4.3.4; Siemens RUGGEDCOM RS900M-GETS-C01 < V4.3.4; Siemens RUGGEDCOM RS900M-GETS-XX < V4.3.4; Siemens RUGGEDCOM RS900M-STND-C01 < V4.3.4; Siemens RUGGEDCOM RS900M-STND-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-GETS-C01 < V4.3.4; Siemens RUGGEDCOM RS900MNC-GETS-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-STND-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-STND-XX-C01 < V4.3.4; Siemens RUGGEDCOM RS900NC < V4.3.4; Siemens RUGGEDCOM RS900NC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900NC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900W < V4.3.4; Siemens RUGGEDCOM RS910 < V4.3.4; Siemens RUGGEDCOM RS910L < V4.3.4; Siemens RUGGEDCOM RS910LNC < V4.3.4; Siemens RUGGEDCOM RS910NC < V4.3.4; Siemens RUGGEDCOM RS910W < V4.3.4; Siemens RUGGEDCOM RS920L < V4.3.4; Siemens RUGGEDCOM RS920LNC < V4.3.4; Siemens RUGGEDCOM RS920W < V4.3.4; Siemens RUGGEDCOM RS930L < V4.3.4; Siemens RUGGEDCOM RS930LNC < V4.3.4; Siemens RUGGEDCOM RS930W < V4.3.4; Siemens RUGGEDCOM RS940G < V4.3.4; Siemens RUGGEDCOM RS940GNC < V4.3.4; Siemens RUGGEDCOM RS969 < V4.3.4; Siemens RUGGEDCOM RS969NC < V4.3.4; Siemens RUGGEDCOM RSG2100 < V4.3.4; Siemens RUGGEDCOM RSG2100 (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100 (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100NC < V4.3.4; Siemens RUGGEDCOM RSG2100NC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100NC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100P < V4.3.4; Siemens RUGGEDCOM RSG2100P (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100P (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100PNC < V4.3.4; Siemens RUGGEDCOM RSG2100PNC (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100PNC (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2200 < V4.3.4; Siemens RUGGEDCOM RSG2200NC < V4.3.4; Siemens RUGGEDCOM RSG2288 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2288 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2288NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2288NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300P V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300P V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300PNC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300PNC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2488 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2488 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2488NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2488NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG907R < V5.0.1; Siemens RUGGEDCOM RSG908C < V5.0.1; Siemens RUGGEDCOM RSG909R < V5.0.1; Siemens RUGGEDCOM RSG910C < V5.0.1; Siemens RUGGEDCOM RSG920P V4.X < V4.3.4; Siemens RUGGEDCOM RSG920P V5.X < V5.0.1; Siemens RUGGEDCOM RSG920PNC V4.X < V4.3.4; Siemens RUGGEDCOM RSG920PNC V5.X < V5.0.1; Siemens RUGGEDCOM RSL910 < V5.0.1; Siemens RUGGEDCOM RSL910NC < V5.0.1; Siemens RUGGEDCOM RST2228 < V5.0.1; Siemens RUGGEDCOM RST2228P < V5.0.1; Siemens RUGGEDCOM RST916C < V5.0.1; Siemens RUGGEDCOM RST916P < V5.0.1; Siemens SCALANCE XB205-3 (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3LD (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3LD (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 (SC) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 (ST/BFOC) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 LD >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 SC >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 ST >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2LD >= V3.0, < V3.0.2; Siemens SCALANCE XB208 (E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB208 (PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (ST, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3LD (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3LD (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB216 (E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB216 (PN) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2 (SC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2 (ST/BFOC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE EEC (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G (EIP DEF.) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208 >= V3.0, < V3.0.2; Siemens SCALANCE XC208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208G >= V3.0, < V3.0.2; Siemens SCALANCE XC208G (EIP def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC208G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC208G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC216 >= V3.0, < V3.0.2; Siemens SCALANCE XC216-3G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC216-3G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G (EIP Def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC216EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC224 >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G (EIP Def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XF204 >= V3.0, < V3.0.2; Siemens SCALANCE XF204 DNA >= V3.0, < V3.0.2; Siemens SCALANCE XF204-2BA >= V3.0, < V3.0.2; Siemens SCALANCE XF204-2BA DNA >= V3.0, < V3.0.2; Siemens SCALANCE XF204G >= V3.0, < V3.0.2; Siemens SCALANCE XM408-4C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-4C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-8C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-8C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XM416-4C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM416-4C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XP208 >= V3.0, < V3.0.2; Siemens SCALANCE XP208 >= V3.0, < V3.0.2; Siemens SCALANCE XP208 (Ethernet/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XP208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G >= V3.0, < V3.0.2; Siemens SCALANCE XP208G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G PP >= V3.0, < V3.0.2; Siemens SCALANCE XP208PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216 >= V3.0, < V3.0.2; Siemens SCALANCE XP216 (Ethernet/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XP216 (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XP216EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216EEC (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XP216G >= V3.0, < V3.0.2; Siemens SCALANCE XP216G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216G PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216POE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216PoE EEC (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XR324WG (24 x FE, AC 230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR324WG (24 X FE, DC 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR326-2C PoE WG >= V3.0, < V3.0.2; Siemens SCALANCE XR326-2C PoE WG (without UL) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR524-8C, 1x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 1x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 24V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 24V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 2x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 2x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 1x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 1x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 24V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 24V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 2x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 2x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (2HR2, L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (2HR2) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2, L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2) >= V6.1.0, < V6.1.1; Siemens SIPLUS NET SCALANCE XC206-2 >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC206-2SFP >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC208 >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC216-4C >= V3.0, < V3.0.2
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
8.8 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
1.07% chance of exploitation in 30 days (percentile 64, 2026-11-26)
CWE
CWE-1188
Published
Modified

Description

After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens RUGGEDCOM i800< V4.3.4—cvelist
Siemens RUGGEDCOM i800NC< V4.3.4—cvelist
Siemens RUGGEDCOM i801< V4.3.4—cvelist
Siemens RUGGEDCOM i801NC< V4.3.4—cvelist
Siemens RUGGEDCOM i802< V4.3.4—cvelist
Siemens RUGGEDCOM i802NC< V4.3.4—cvelist
Siemens RUGGEDCOM i803< V4.3.4—cvelist
Siemens RUGGEDCOM i803NC< V4.3.4—cvelist
Siemens RUGGEDCOM M2100< V4.3.4—cvelist
Siemens RUGGEDCOM M2100NC< V4.3.4—cvelist
Siemens RUGGEDCOM M2200< V4.3.4—cvelist
Siemens RUGGEDCOM M2200NC< V4.3.4—cvelist
Siemens RUGGEDCOM M969< V4.3.4—cvelist
Siemens RUGGEDCOM M969NC< V4.3.4—cvelist
Siemens RUGGEDCOM RMC30< V4.3.4—cvelist
Siemens RUGGEDCOM RMC30NC< V4.3.4—cvelist
Siemens RUGGEDCOM RMC8388 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RMC8388 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RMC8388NC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RMC8388NC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RP110< V4.3.4—cvelist
Siemens RUGGEDCOM RP110NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600F< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600FNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600T< V4.3.4—cvelist
Siemens RUGGEDCOM RS1600TNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS400< V4.3.4—cvelist
Siemens RUGGEDCOM RS400NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS401< V4.3.4—cvelist
Siemens RUGGEDCOM RS401NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS416< V4.3.4—cvelist
Siemens RUGGEDCOM RS416NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS416NCv2 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS416NCv2 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS416P< V4.3.4—cvelist
Siemens RUGGEDCOM RS416PNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS416PNCv2 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS416PNCv2 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS416Pv2 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS416Pv2 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS416v2 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS416v2 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS8000< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000A< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000ANC< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000H< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000HNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000T< V4.3.4—cvelist
Siemens RUGGEDCOM RS8000TNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS900< V4.3.4—cvelist
Siemens RUGGEDCOM RS900 (32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS900 (32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS900G< V4.3.4—cvelist
Siemens RUGGEDCOM RS900G (32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS900G (32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS900GNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS900GNC(32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS900GNC(32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS900GP< V4.3.4—cvelist
Siemens RUGGEDCOM RS900GPNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS900L< V4.3.4—cvelist
Siemens RUGGEDCOM RS900LNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS900M-GETS-C01< V4.3.4—cvelist
Siemens RUGGEDCOM RS900M-GETS-XX< V4.3.4—cvelist
Siemens RUGGEDCOM RS900M-STND-C01< V4.3.4—cvelist
Siemens RUGGEDCOM RS900M-STND-XX< V4.3.4—cvelist
Siemens RUGGEDCOM RS900MNC-GETS-C01< V4.3.4—cvelist
Siemens RUGGEDCOM RS900MNC-GETS-XX< V4.3.4—cvelist
Siemens RUGGEDCOM RS900MNC-STND-XX< V4.3.4—cvelist
Siemens RUGGEDCOM RS900MNC-STND-XX-C01< V4.3.4—cvelist
Siemens RUGGEDCOM RS900NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS900NC(32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RS900NC(32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RS900W< V4.3.4—cvelist
Siemens RUGGEDCOM RS910< V4.3.4—cvelist
Siemens RUGGEDCOM RS910L< V4.3.4—cvelist
Siemens RUGGEDCOM RS910LNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS910NC< V4.3.4—cvelist
Siemens RUGGEDCOM RS910W< V4.3.4—cvelist
Siemens RUGGEDCOM RS920L< V4.3.4—cvelist
Siemens RUGGEDCOM RS920LNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS920W< V4.3.4—cvelist
Siemens RUGGEDCOM RS930L< V4.3.4—cvelist
Siemens RUGGEDCOM RS930LNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS930W< V4.3.4—cvelist
Siemens RUGGEDCOM RS940G< V4.3.4—cvelist
Siemens RUGGEDCOM RS940GNC< V4.3.4—cvelist
Siemens RUGGEDCOM RS969< V4.3.4—cvelist
Siemens RUGGEDCOM RS969NC< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100 (32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100 (32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2100NC< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100NC(32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100NC(32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2100P< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100P (32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100P (32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2100PNC< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100PNC (32M) V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2100PNC (32M) V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2200< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2200NC< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2288 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2288 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2288NC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2288NC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2300 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2300 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2300NC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2300NC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2300P V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2300P V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2300PNC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2300PNC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2488 V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2488 V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG2488NC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG2488NC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG907R< V5.0.1—cvelist
Siemens RUGGEDCOM RSG908C< V5.0.1—cvelist
Siemens RUGGEDCOM RSG909R< V5.0.1—cvelist
Siemens RUGGEDCOM RSG910C< V5.0.1—cvelist
Siemens RUGGEDCOM RSG920P V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG920P V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSG920PNC V4.X< V4.3.4—cvelist
Siemens RUGGEDCOM RSG920PNC V5.X< V5.0.1—cvelist
Siemens RUGGEDCOM RSL910< V5.0.1—cvelist
Siemens RUGGEDCOM RSL910NC< V5.0.1—cvelist
Siemens RUGGEDCOM RST2228< V5.0.1—cvelist
Siemens RUGGEDCOM RST2228P< V5.0.1—cvelist
Siemens RUGGEDCOM RST916C< V5.0.1—cvelist
Siemens RUGGEDCOM RST916P< V5.0.1—cvelist
Siemens SCALANCE XB205-3 (SC, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB205-3 (ST, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB205-3 (ST, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB205-3 (ST, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB205-3LD (SC, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB205-3LD (SC, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2 (SC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2 (ST/BFOC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2 LD>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2 SC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2 ST>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB206-2LD>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB208 (E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB208 (PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3 (SC, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3 (SC, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3 (ST, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3 (ST, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3LD (SC, E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB213-3LD (SC, PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB216 (E/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XB216 (PN)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2 (SC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2 (ST/BFOC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2G PoE>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2G PoE (54 V DC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2G PoE EEC (54 V DC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2SFP>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2SFP EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2SFP G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2SFP G (EIP DEF.)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC206-2SFP G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208G (EIP def.)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208G PoE>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC208G PoE (54 V DC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-3G PoE>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-3G PoE (54 V DC)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-4C>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-4C G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-4C G (EIP Def.)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216-4C G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC216EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC224>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC224-4C G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC224-4C G (EIP Def.)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XC224-4C G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XF204>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XF204 DNA>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XF204-2BA>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XF204-2BA DNA>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XF204G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XM408-4C>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XM408-4C (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XM408-8C>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XM408-8C (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XM416-4C>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XM416-4C (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XP208>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208 (Ethernet/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208G PoE EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208G PP>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208PoE EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP208PoE EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216 (Ethernet/IP)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216 (V2)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216EEC (V2)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216G>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216G EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216G PoE EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216POE EEC>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XP216PoE EEC (V2)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR324WG (24 x FE, AC 230V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR324WG (24 X FE, DC 24V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR326-2C PoE WG>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR326-2C PoE WG (without UL)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V)>= V3.0, < V3.0.2—cvelist
Siemens SCALANCE XR524-8C, 1x230V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR524-8C, 1x230V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR524-8C, 24V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR524-8C, 24V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR524-8C, 2x230V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR524-8C, 2x230V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 1x230V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 1x230V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 24V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 24V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 2x230V>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR526-8C, 2x230V (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR528-6M>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR528-6M (2HR2, L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR528-6M (2HR2)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR528-6M (L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR552-12M>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR552-12M (2HR2, L3 int.)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR552-12M (2HR2)>= V6.1.0, < V6.1.1—cvelist
Siemens SCALANCE XR552-12M (2HR2)>= V6.1.0, < V6.1.1—cvelist
Siemens SIPLUS NET SCALANCE XC206-2>= V3.0, < V3.0.2—cvelist
Siemens SIPLUS NET SCALANCE XC206-2SFP>= V3.0, < V3.0.2—cvelist
Siemens SIPLUS NET SCALANCE XC208>= V3.0, < V3.0.2—cvelist
Siemens SIPLUS NET SCALANCE XC216-4C>= V3.0, < V3.0.2—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-12736. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-12736.md
Affected: Siemens RUGGEDCOM i800 < V4.3.4; Siemens RUGGEDCOM i800NC < V4.3.4; Siemens RUGGEDCOM i801 < V4.3.4; Siemens RUGGEDCOM i801NC < V4.3.4; Siemens RUGGEDCOM i802 < V4.3.4; Siemens RUGGEDCOM i802NC < V4.3.4; Siemens RUGGEDCOM i803 < V4.3.4; Siemens RUGGEDCOM i803NC < V4.3.4; Siemens RUGGEDCOM M2100 < V…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens RUGGEDCOM i800, Siemens RUGGEDCOM i800NC, Siemens RUGGEDCOM i801, Siemens RUGGEDCOM i801NC, Siemens RUGGEDCOM i802, Siemens RUGGEDCOM i802NC: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-12736 being exploited?

There is no confirmed exploitation: CVE-2017-12736 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.07% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-12736?

High: CVSS 8.8 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2017-12736?

Siemens RUGGEDCOM i800 < V4.3.4; Siemens RUGGEDCOM i800NC < V4.3.4; Siemens RUGGEDCOM i801 < V4.3.4; Siemens RUGGEDCOM i801NC < V4.3.4; Siemens RUGGEDCOM i802 < V4.3.4; Siemens RUGGEDCOM i802NC < V4.3.4; Siemens RUGGEDCOM i803 < V4.3.4; Siemens RUGGEDCOM i803NC < V4.3.4; Siemens RUGGEDCOM M2100 < V4.3.4; Siemens RUGGEDCOM M2100NC < V4.3.4; Siemens RUGGEDCOM M2200 < V4.3.4; Siemens RUGGEDCOM M2200NC < V4.3.4; Siemens RUGGEDCOM M969 < V4.3.4; Siemens RUGGEDCOM M969NC < V4.3.4; Siemens RUGGEDCOM RMC30 < V4.3.4; Siemens RUGGEDCOM RMC30NC < V4.3.4; Siemens RUGGEDCOM RMC8388 V4.X < V4.3.4; Siemens RUGGEDCOM RMC8388 V5.X < V5.0.1; Siemens RUGGEDCOM RMC8388NC V4.X < V4.3.4; Siemens RUGGEDCOM RMC8388NC V5.X < V5.0.1; Siemens RUGGEDCOM RP110 < V4.3.4; Siemens RUGGEDCOM RP110NC < V4.3.4; Siemens RUGGEDCOM RS1600 < V4.3.4; Siemens RUGGEDCOM RS1600F < V4.3.4; Siemens RUGGEDCOM RS1600FNC < V4.3.4; Siemens RUGGEDCOM RS1600NC < V4.3.4; Siemens RUGGEDCOM RS1600T < V4.3.4; Siemens RUGGEDCOM RS1600TNC < V4.3.4; Siemens RUGGEDCOM RS400 < V4.3.4; Siemens RUGGEDCOM RS400NC < V4.3.4; Siemens RUGGEDCOM RS401 < V4.3.4; Siemens RUGGEDCOM RS401NC < V4.3.4; Siemens RUGGEDCOM RS416 < V4.3.4; Siemens RUGGEDCOM RS416NC < V4.3.4; Siemens RUGGEDCOM RS416NCv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416NCv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416P < V4.3.4; Siemens RUGGEDCOM RS416PNC < V4.3.4; Siemens RUGGEDCOM RS416PNCv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416PNCv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416Pv2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416Pv2 V5.X < V5.0.1; Siemens RUGGEDCOM RS416v2 V4.X < V4.3.4; Siemens RUGGEDCOM RS416v2 V5.X < V5.0.1; Siemens RUGGEDCOM RS8000 < V4.3.4; Siemens RUGGEDCOM RS8000A < V4.3.4; Siemens RUGGEDCOM RS8000ANC < V4.3.4; Siemens RUGGEDCOM RS8000H < V4.3.4; Siemens RUGGEDCOM RS8000HNC < V4.3.4; Siemens RUGGEDCOM RS8000NC < V4.3.4; Siemens RUGGEDCOM RS8000T < V4.3.4; Siemens RUGGEDCOM RS8000TNC < V4.3.4; Siemens RUGGEDCOM RS900 < V4.3.4; Siemens RUGGEDCOM RS900 (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900 (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900G < V4.3.4; Siemens RUGGEDCOM RS900G (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900G (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900GNC < V4.3.4; Siemens RUGGEDCOM RS900GNC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900GNC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900GP < V4.3.4; Siemens RUGGEDCOM RS900GPNC < V4.3.4; Siemens RUGGEDCOM RS900L < V4.3.4; Siemens RUGGEDCOM RS900LNC < V4.3.4; Siemens RUGGEDCOM RS900M-GETS-C01 < V4.3.4; Siemens RUGGEDCOM RS900M-GETS-XX < V4.3.4; Siemens RUGGEDCOM RS900M-STND-C01 < V4.3.4; Siemens RUGGEDCOM RS900M-STND-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-GETS-C01 < V4.3.4; Siemens RUGGEDCOM RS900MNC-GETS-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-STND-XX < V4.3.4; Siemens RUGGEDCOM RS900MNC-STND-XX-C01 < V4.3.4; Siemens RUGGEDCOM RS900NC < V4.3.4; Siemens RUGGEDCOM RS900NC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RS900NC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RS900W < V4.3.4; Siemens RUGGEDCOM RS910 < V4.3.4; Siemens RUGGEDCOM RS910L < V4.3.4; Siemens RUGGEDCOM RS910LNC < V4.3.4; Siemens RUGGEDCOM RS910NC < V4.3.4; Siemens RUGGEDCOM RS910W < V4.3.4; Siemens RUGGEDCOM RS920L < V4.3.4; Siemens RUGGEDCOM RS920LNC < V4.3.4; Siemens RUGGEDCOM RS920W < V4.3.4; Siemens RUGGEDCOM RS930L < V4.3.4; Siemens RUGGEDCOM RS930LNC < V4.3.4; Siemens RUGGEDCOM RS930W < V4.3.4; Siemens RUGGEDCOM RS940G < V4.3.4; Siemens RUGGEDCOM RS940GNC < V4.3.4; Siemens RUGGEDCOM RS969 < V4.3.4; Siemens RUGGEDCOM RS969NC < V4.3.4; Siemens RUGGEDCOM RSG2100 < V4.3.4; Siemens RUGGEDCOM RSG2100 (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100 (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100NC < V4.3.4; Siemens RUGGEDCOM RSG2100NC(32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100NC(32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100P < V4.3.4; Siemens RUGGEDCOM RSG2100P (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100P (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2100PNC < V4.3.4; Siemens RUGGEDCOM RSG2100PNC (32M) V4.X < V4.3.4; Siemens RUGGEDCOM RSG2100PNC (32M) V5.X < V5.0.1; Siemens RUGGEDCOM RSG2200 < V4.3.4; Siemens RUGGEDCOM RSG2200NC < V4.3.4; Siemens RUGGEDCOM RSG2288 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2288 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2288NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2288NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300P V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300P V5.X < V5.0.1; Siemens RUGGEDCOM RSG2300PNC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2300PNC V5.X < V5.0.1; Siemens RUGGEDCOM RSG2488 V4.X < V4.3.4; Siemens RUGGEDCOM RSG2488 V5.X < V5.0.1; Siemens RUGGEDCOM RSG2488NC V4.X < V4.3.4; Siemens RUGGEDCOM RSG2488NC V5.X < V5.0.1; Siemens RUGGEDCOM RSG907R < V5.0.1; Siemens RUGGEDCOM RSG908C < V5.0.1; Siemens RUGGEDCOM RSG909R < V5.0.1; Siemens RUGGEDCOM RSG910C < V5.0.1; Siemens RUGGEDCOM RSG920P V4.X < V4.3.4; Siemens RUGGEDCOM RSG920P V5.X < V5.0.1; Siemens RUGGEDCOM RSG920PNC V4.X < V4.3.4; Siemens RUGGEDCOM RSG920PNC V5.X < V5.0.1; Siemens RUGGEDCOM RSL910 < V5.0.1; Siemens RUGGEDCOM RSL910NC < V5.0.1; Siemens RUGGEDCOM RST2228 < V5.0.1; Siemens RUGGEDCOM RST2228P < V5.0.1; Siemens RUGGEDCOM RST916C < V5.0.1; Siemens RUGGEDCOM RST916P < V5.0.1; Siemens SCALANCE XB205-3 (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3 (ST, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3LD (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB205-3LD (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 (SC) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 (ST/BFOC) >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 LD >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 SC >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2 ST >= V3.0, < V3.0.2; Siemens SCALANCE XB206-2LD >= V3.0, < V3.0.2; Siemens SCALANCE XB208 (E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB208 (PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (ST, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3 (ST, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3LD (SC, E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB213-3LD (SC, PN) >= V3.0, < V3.0.2; Siemens SCALANCE XB216 (E/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XB216 (PN) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2 (SC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2 (ST/BFOC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2G PoE EEC (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G (EIP DEF.) >= V3.0, < V3.0.2; Siemens SCALANCE XC206-2SFP G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208 >= V3.0, < V3.0.2; Siemens SCALANCE XC208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208G >= V3.0, < V3.0.2; Siemens SCALANCE XC208G (EIP def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC208G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC208G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC208G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC216 >= V3.0, < V3.0.2; Siemens SCALANCE XC216-3G PoE >= V3.0, < V3.0.2; Siemens SCALANCE XC216-3G PoE (54 V DC) >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G (EIP Def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC216-4C G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC216EEC >= V3.0, < V3.0.2; Siemens SCALANCE XC224 >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G (EIP Def.) >= V3.0, < V3.0.2; Siemens SCALANCE XC224-4C G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XF204 >= V3.0, < V3.0.2; Siemens SCALANCE XF204 DNA >= V3.0, < V3.0.2; Siemens SCALANCE XF204-2BA >= V3.0, < V3.0.2; Siemens SCALANCE XF204-2BA DNA >= V3.0, < V3.0.2; Siemens SCALANCE XF204G >= V3.0, < V3.0.2; Siemens SCALANCE XM408-4C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-4C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-8C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM408-8C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XM416-4C >= V6.1.0, < V6.1.1; Siemens SCALANCE XM416-4C (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XP208 >= V3.0, < V3.0.2; Siemens SCALANCE XP208 >= V3.0, < V3.0.2; Siemens SCALANCE XP208 (Ethernet/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XP208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G >= V3.0, < V3.0.2; Siemens SCALANCE XP208G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208G PP >= V3.0, < V3.0.2; Siemens SCALANCE XP208PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP208PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216 >= V3.0, < V3.0.2; Siemens SCALANCE XP216 (Ethernet/IP) >= V3.0, < V3.0.2; Siemens SCALANCE XP216 (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XP216EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216EEC (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XP216G >= V3.0, < V3.0.2; Siemens SCALANCE XP216G EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216G PoE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216POE EEC >= V3.0, < V3.0.2; Siemens SCALANCE XP216PoE EEC (V2) >= V3.0, < V3.0.2; Siemens SCALANCE XR324WG (24 x FE, AC 230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR324WG (24 X FE, DC 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR326-2C PoE WG >= V3.0, < V3.0.2; Siemens SCALANCE XR326-2C PoE WG (without UL) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) >= V3.0, < V3.0.2; Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) >= V3.0, < V3.0.2; Siemens SCALANCE XR524-8C, 1x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 1x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 24V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 24V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 2x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR524-8C, 2x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 1x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 1x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 24V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 24V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 2x230V >= V6.1.0, < V6.1.1; Siemens SCALANCE XR526-8C, 2x230V (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (2HR2, L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (2HR2) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR528-6M (L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2, L3 int.) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2) >= V6.1.0, < V6.1.1; Siemens SCALANCE XR552-12M (2HR2) >= V6.1.0, < V6.1.1; Siemens SIPLUS NET SCALANCE XC206-2 >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC206-2SFP >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC208 >= V3.0, < V3.0.2; Siemens SIPLUS NET SCALANCE XC216-4C >= V3.0, < V3.0.2.

Is there a fix for CVE-2017-12736?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-12736?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors