CVE-2017-12726

HIGH 7.3EPSS 65%

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Vers…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump

Vulnerability facts

Affected
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.3 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: Low
  • Availability impact: Low
EPSS
1.08% chance of exploitation in 30 days (percentile 65, 2026-11-26)
CWE
CWE-798
Published
Modified

Description

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.

Affected and fixed versions

Package / productAffectedFixedSource
Smiths Medical Medfusion 4000 Wireless Syringe Infusion PumpSmiths Medical Medfusion 4000 Wireless Syringe Infusion Pump—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-12726. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-12726.md
Affected: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-12726 being exploited?

There is no confirmed exploitation: CVE-2017-12726 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.08% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-12726?

High: CVSS 7.3 (v3.0, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2017-12726?

Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump.

Is there a fix for CVE-2017-12726?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-12726?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors