CVE-2017-12722
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Vulnerability facts
- Affected
- Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.3 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- EPSS
- 2.42% chance of exploitation in 30 days (percentile 85, 2026-11-26)
- CWE
- CWE-125
- Modified
Description
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump | Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-12722. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-12722.md Affected: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2017-12722 being exploited?
There is no confirmed exploitation: CVE-2017-12722 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.42% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-12722?
Medium: CVSS 5.3 (v3.0, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2017-12722?
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump.
Is there a fix for CVE-2017-12722?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-12722?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.