CVE-2017-12718
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version…
Also known as EDB-43776
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Vulnerability facts
- Affected
- Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v3.0, NVD)CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 12.78% chance of exploitation in 30 days (percentile 97, 2026-11-26)
- CWE
- CWE-120
- Modified
Description
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump | Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2017-12718. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2017-12718.md Affected: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Exploits and PoCs
FAQ
Is CVE-2017-12718 being exploited?
There is no confirmed exploitation: CVE-2017-12718 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 12.78% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2017-12718?
High: CVSS 8.1 (v3.0, scored by NVD). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2017-12718?
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump.
Is there a fix for CVE-2017-12718?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2017-12718?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.