Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2017-12714

MEDIUM 6.5EPSS 45%

Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly form…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. All versions of pacemakers manufactured prior to August 28, 2017

Vulnerability facts

Affected
Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. All versions of pacemakers manufactured prior to August 28, 2017
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
6.5 (v3.0, NVD)CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
0.63% chance of exploitation in 30 days (percentile 45, 2026-11-26)
CWE
CWE-920
Published
Modified

Description

Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.

Affected and fixed versions

Package / productAffectedFixedSource
Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.All versions of pacemakers manufactured prior to August 28, 2017—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2017-12714. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-12714.md
Affected: Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. All versions of pacemakers manufactured prior to August 28, 2017
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2017-12714 being exploited?

There is no confirmed exploitation: CVE-2017-12714 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.63% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2017-12714?

Medium: CVSS 6.5 (v3.0, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2017-12714?

Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. All versions of pacemakers manufactured prior to August 28, 2017.

Is there a fix for CVE-2017-12714?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2017-12714?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors