# CVE-2017-10608: SRX series: Junos OS: SRX series using IPv6 Sun/MS-RPC ALGs may experience flowd crash on processing packets.

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.0, CNA) `CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.03% (percentile 63, 2026-11-26)
- **CWE:** CWE-400
- **Published:** 2017-10-13T17:00:00.000Z
- **Modified:** 2026-06-17T01:00:26.263Z

## Who should check

- Anyone running Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35; 15.1X49 prior to 15.1X49-D60

## Description

Any Juniper Networks SRX series device with one or more ALGs enabled may experience a flowd crash when traffic is processed by the Sun/MS-RPC ALGs. This vulnerability in the Sun/MS-RPC ALG services component of Junos OS allows an attacker to cause a repeated denial of service against the target. Repeated traffic in a cluster may cause repeated flip-flop failure operations or full failure to the flowd daemon halting traffic on all nodes. Only IPv6 traffic is affected by this issue. IPv4 traffic is unaffected. This issues is not seen with to-host traffic. This issue has no relation with HA services themselves, only the ALG service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55 on SRX; 12.1X47 prior to 12.1X47-D45 on SRX; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35 on SRX; 15.1X49 prior to 15.1X49-D60 on SRX.

## Affected and fixed versions

- Juniper Networks Junos OS: 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35; 15.1X49 prior to 15.1X49-D60 (cvelist)

## Mitigation

- Vendor workaround: Disable Sun/MS-RPC ALGs on the SRX Series device. 
- Disable IPv6 on the device.
- example: 
- deactivate interfaces xe-0/0/0 unit 0 family inet6 address 2000::254/64
-  
- 
- Filtering incoming IPv6, or Sun/MS-RPC from the device is also an option.
- example: 
- 
- set interfaces xe-0/0/0 unit 0 family inet6 filter input TEST ==\> apply to interface
- set firewall family inet6 filter TEST term t1 from destination-port 135
- set firewall family inet6 filter TEST term t1 then discard

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2017-10608. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2017-10608.md
Affected: Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35; 15.1X49 prior to 15.1X49-D60
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Juniper Networks Junos OS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2017-10608 being exploited?

There is no confirmed exploitation: CVE-2017-10608 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.03% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2017-10608?

High: CVSS 7.5 (v3.0, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2017-10608?

Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35; 15.1X49 prior to 15.1X49-D60.

### Is there a fix for CVE-2017-10608?

No fixed version is listed in the sources yet. Vendor workaround: Disable Sun/MS-RPC ALGs on the SRX Series device.  Disable IPv6 on the device. example:  deactivate interfaces xe-0/0/0 unit 0 family inet6 address 2000::254/64    Filtering incoming IPv6, or Sun/MS-RPC from the device is also an option. example:   set interfaces xe-0/0/0 unit 0 family inet6 filter input TEST ==\> apply to interface set firewall family inet6 filter TEST term t1 from destination-port 135 set firewall family inet6 filter TEST term t1 then discard

### How do I check if I'm affected by CVE-2017-10608?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://kb.juniper.net/JSA10811>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2017-10608>

HTML: <https://flawdb.com/CVE-2017-10608> · JSON: <https://flawdb.com/api/v1/entries/CVE-2017-10608>