CVE-2016-8355

CRITICAL 9.9EPSS 74%

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-S…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Smiths-Medical CADD-Solis Medication Safety Software through 3.1

Vulnerability facts

Affected
Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Smiths-Medical CADD-Solis Medication Safety Software through 3.1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
9.9 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
1.49% chance of exploitation in 30 days (percentile 74, 2026-11-26)
CWE
CWE-306
Published
Modified

Description

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates.

Affected and fixed versions

Package / productAffectedFixedSource
Smiths-Medical CADD-Solis Medication Safety Software through 3.1Smiths-Medical CADD-Solis Medication Safety Software through 3.1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2016-8355. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2016-8355.md
Affected: Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Smiths-Medical CADD-Solis Medication Safety Software through 3.1
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Smiths-Medical CADD-Solis Medication Safety Software through 3.1: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2016-8355 being exploited?

There is no confirmed exploitation: CVE-2016-8355 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.49% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2016-8355?

Critical: CVSS 9.9 (v3.0, scored by NVD). Remote, login needed.

Which versions are affected by CVE-2016-8355?

Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Smiths-Medical CADD-Solis Medication Safety Software through 3.1.

Is there a fix for CVE-2016-8355?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2016-8355?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors