Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2016-7987

HIGH 7.5EPSS 82%

An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module fo…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SICAM RTU Devices before 08 Siemens SICAM RTU Devices before 08

Vulnerability facts

Affected
Siemens SICAM RTU Devices before 08 Siemens SICAM RTU Devices before 08
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
2.05% chance of exploitation in 30 days (percentile 82, 2026-11-26)
CWE
CWE-19
Published
Modified

Description

An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SICAM RTU Devices before 08Siemens SICAM RTU Devices before 08—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2016-7987. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2016-7987.md
Affected: Siemens SICAM RTU Devices before 08 Siemens SICAM RTU Devices before 08
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SICAM RTU Devices before 08: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2016-7987 being exploited?

There is no confirmed exploitation: CVE-2016-7987 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.05% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2016-7987?

High: CVSS 7.5 (v3.0, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2016-7987?

Siemens SICAM RTU Devices before 08 Siemens SICAM RTU Devices before 08.

Is there a fix for CVE-2016-7987?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2016-7987?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors