Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2016-5809

HIGH 8.8PoCEPSS 82%

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX serie…

Also known as EDB-44640

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Schneider Electric IONXXXX Series Schneider Electric IONXXXX Series

Vulnerability facts

Affected
Schneider Electric IONXXXX Series Schneider Electric IONXXXX Series
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
8.8 (v3.0, NVD)CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: Required
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
2.04% chance of exploitation in 30 days (percentile 82, 2026-11-26)
CWE
CWE-352
Published
Modified

Description

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric IONXXXX SeriesSchneider Electric IONXXXX Series—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2016-5809. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2016-5809.md
Affected: Schneider Electric IONXXXX Series Schneider Electric IONXXXX Series
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric IONXXXX Series: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2016-5809 being exploited?

There is no confirmed exploitation: CVE-2016-5809 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.04% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2016-5809?

High: CVSS 8.8 (v3.0, scored by NVD). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2016-5809?

Schneider Electric IONXXXX Series Schneider Electric IONXXXX Series.

Is there a fix for CVE-2016-5809?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2016-5809?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors