# CVE-2016-5638: Netgear WNDR4500 running firmware version V1.0.1.40\_1.0.6877 reveals some sensitive information such as 2.4GHz & 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.0, NVD) `CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: None; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** Yes (see exploit references)
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 2.69% (percentile 87, 2026-11-26)
- **CWE:** CWE-319
- **Published:** 2018-07-24T15:00:00.000Z
- **Modified:** 2026-06-17T00:49:48.320Z

## Who should check

- Anyone running Netgear WNDR4500 V1.0.1.40\_1.0.6877

## Description

There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40\_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie\_ping.htm or genie\_ping2.htm or genie\_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz & 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text.

## Affected and fixed versions

- Netgear WNDR4500: V1.0.1.40\_1.0.6877 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2016-5638. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2016-5638.md
Affected: Netgear WNDR4500 V1.0.1.40_1.0.6877
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Netgear WNDR4500: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2016-5638 being exploited?

There is no confirmed exploitation: CVE-2016-5638 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 2.69% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2016-5638?

High: CVSS 7.5 (v3.0, scored by NVD). Remote, no login needed.

### Which versions are affected by CVE-2016-5638?

Netgear WNDR4500 V1.0.1.40\_1.0.6877.

### Is there a fix for CVE-2016-5638?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2016-5638?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- exploit: <https://packetstormsecurity.com/files/140342/Netgear-DGN2200-DGND3700-WNDR4500-Information-Disclosure.html>