Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2014-5407

MEDIUM 4.1EPSS 23%

Schneider Electric VAMPSET Stack-based Buffer Overflow

Mitigation

  • Vendor workaround: To protect the computer and configuration files from unauthorized
  • escalation of privileges through manipulation, Schneider Electric
  • recommends users employ best IT practices to secure their computers and
  • relay’s configuration files and to use User Access Control (UAC) to
  • further improve the security of the computer. Additionally, to minimize
  • the risk of attack, users who are not directly using this software on a
  • regular basis are strongly encouraged to delete this application from
  • their computer to reduce the likelihood of attack and to store relay
  • configuration files in the client’s protected location.

Who should check

  • Anyone running Schneider Electric VAMPSET <= 2.2.136

Vulnerability facts

Affected
Schneider Electric VAMPSET <= 2.2.136
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
4.1 (v2.0, CNA)AV:L/AC:M/Au:S/C:P/I:P/A:P
Show all 6 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Medium
  • Authentication: Single
  • Confidentiality impact: Partial
  • Integrity impact: Partial
  • Availability impact: Partial
EPSS
0.37% chance of exploitation in 30 days (percentile 23, 2026-11-26)
CWE
CWE-121
Published
Modified

Description

Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.

Affected and fixed versions

Package / productAffectedFixedSource
Schneider Electric VAMPSET<= 2.2.136—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2014-5407. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2014-5407.md
Affected: Schneider Electric VAMPSET <= 2.2.136
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Schneider Electric VAMPSET: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2014-5407 being exploited?

There is no confirmed exploitation: CVE-2014-5407 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.37% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2014-5407?

Medium: CVSS 4.1 (v2.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2014-5407?

Schneider Electric VAMPSET <= 2.2.136.

Is there a fix for CVE-2014-5407?

No fixed version is listed in the sources yet. Vendor workaround: To protect the computer and configuration files from unauthorized escalation of privileges through manipulation, Schneider Electric recommends users employ best IT practices to secure their computers and relay’s configuration files and to use User Access Control (UAC) to further improve the security of the computer. Additionally, to minimize the risk of attack, users who are not directly using this software on a regular basis are strongly encouraged to delete this application from their computer to reduce the likelihood of attack and to store relay configuration files in the client’s protected location.

How do I check if I'm affected by CVE-2014-5407?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors