CVE-2014-0789
Schneider Electric OPC Factory Server Buffer Overflow
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Schneider Electric OPC Factory Server (OFS) <= TLXCDSUOFS33 – V3.5; <= TLXCDSTOFS33 – V3.5; <= TLXCDLUOFS33 – V3.5; <= TLXCDLTOFS33 – V3.5; <= TLXCDLFOFS33 – V3.5
Vulnerability facts
- Affected
- Schneider Electric OPC Factory Server (OFS) <= TLXCDSUOFS33 – V3.5; <= TLXCDSTOFS33 – V3.5; <= TLXCDLUOFS33 – V3.5; <= TLXCDLTOFS33 – V3.5; <= TLXCDLFOFS33 – V3.5
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.0 (v2.0, CNA)AV:N/AC:L/Au:N/C:N/I:N/A:P
Show all 6 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Authentication: None
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Partial
- EPSS
- 2.47% chance of exploitation in 30 days (percentile 85, 2026-11-26)
- CWE
- CWE-122
- Modified
Description
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Schneider Electric OPC Factory Server (OFS) | <= TLXCDSUOFS33 – V3.5; <= TLXCDSTOFS33 – V3.5; <= TLXCDLUOFS33 – V3.5; <= TLXCDLTOFS33 – V3.5; <= TLXCDLFOFS33 – V3.5 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2014-0789. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2014-0789.md Affected: Schneider Electric OPC Factory Server (OFS) <= TLXCDSUOFS33 – V3.5; <= TLXCDSTOFS33 – V3.5; <= TLXCDLUOFS33 – V3.5; <= TLXCDLTOFS33 – V3.5; <= TLXCDLFOFS33 – V3.5 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Schneider Electric OPC Factory Server (OFS): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2014-0789 being exploited?
There is no confirmed exploitation: CVE-2014-0789 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.47% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2014-0789?
Medium: CVSS 5.0 (v2.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2014-0789?
Schneider Electric OPC Factory Server (OFS) <= TLXCDSUOFS33 – V3.5; <= TLXCDSTOFS33 – V3.5; <= TLXCDLUOFS33 – V3.5; <= TLXCDLTOFS33 – V3.5; <= TLXCDLFOFS33 – V3.5.
Is there a fix for CVE-2014-0789?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2014-0789?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.