CVE-2014-0750
GE Proficy HMI/SCADA Path Traversal
Also known as EDB-31987
Mitigation
- Upgrade Proficy HMI/SCADA - CIMPLICITY to 8.2 or later.
Who should check
- Anyone running GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2
- Anyone running GE Proficy Process Systems with CIMPLICITY all versions
Vulnerability facts
- Affected
- GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions
- Fixed in
- GE Proficy HMI/SCADA - CIMPLICITY 8.2
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v2.0, CNA)AV:N/AC:L/Au:N/C:P/I:P/A:P
Show all 6 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Authentication: None
- Confidentiality impact: Partial
- Integrity impact: Partial
- Availability impact: Partial
- EPSS
- 69.83% chance of exploitation in 30 days (percentile 100, 2026-11-26)
- CWE
- CWE-22
- Modified
Description
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2014-0750. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2014-0750.md Affected: GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions Fixed in: GE Proficy HMI/SCADA - CIMPLICITY 8.2 Steps: 1. Search this machine and project for GE Proficy HMI/SCADA - CIMPLICITY, GE Proficy Process Systems with CIMPLICITY: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Exploits and PoCs
FAQ
Is CVE-2014-0750 being exploited?
There is no confirmed exploitation: CVE-2014-0750 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 69.83% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2014-0750?
High: CVSS 7.5 (v2.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2014-0750?
GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions.
Is there a fix for CVE-2014-0750?
Yes. Fixed in GE Proficy HMI/SCADA - CIMPLICITY 8.2. Upgrade Proficy HMI/SCADA - CIMPLICITY to 8.2 or later.
How do I check if I'm affected by CVE-2014-0750?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.