CVE-2014-0750

HIGH 7.5PoCEPSS 100%

GE Proficy HMI/SCADA Path Traversal

Also known as EDB-31987

Mitigation

  • Upgrade Proficy HMI/SCADA - CIMPLICITY to 8.2 or later.

Who should check

  • Anyone running GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2
  • Anyone running GE Proficy Process Systems with CIMPLICITY all versions

Vulnerability facts

Affected
GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions
Fixed in
GE Proficy HMI/SCADA - CIMPLICITY 8.2
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
7.5 (v2.0, CNA)AV:N/AC:L/Au:N/C:P/I:P/A:P
Show all 6 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Authentication: None
  • Confidentiality impact: Partial
  • Integrity impact: Partial
  • Availability impact: Partial
EPSS
69.83% chance of exploitation in 30 days (percentile 100, 2026-11-26)
CWE
CWE-22
Published
Modified

Description

Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.

Affected and fixed versions

Package / productAffectedFixedSource
GE Proficy HMI/SCADA - CIMPLICITY>= 4.01, < 8.2—cvelist
GE Proficy Process Systems with CIMPLICITYall versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2014-0750. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2014-0750.md
Affected: GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions
Fixed in: GE Proficy HMI/SCADA - CIMPLICITY 8.2

Steps:
1. Search this machine and project for GE Proficy HMI/SCADA - CIMPLICITY, GE Proficy Process Systems with CIMPLICITY: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2014-0750 being exploited?

There is no confirmed exploitation: CVE-2014-0750 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 69.83% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2014-0750?

High: CVSS 7.5 (v2.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2014-0750?

GE Proficy HMI/SCADA - CIMPLICITY >= 4.01, < 8.2; GE Proficy Process Systems with CIMPLICITY all versions.

Is there a fix for CVE-2014-0750?

Yes. Fixed in GE Proficy HMI/SCADA - CIMPLICITY 8.2. Upgrade Proficy HMI/SCADA - CIMPLICITY to 8.2 or later.

How do I check if I'm affected by CVE-2014-0750?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors